Wall Mounted Meter Box
Boundary Boxes
Wall Boxes
Benefits
The Atplas Intex 2 is a purpose designed alternative to
traditional underground meter chamber systems for new
domestic or small commercial water connections. Intex 2 is
designed to be built into the wall of a property during its
construction and offers particular advantages over some
underground chamber systems especially in areas of
contaminated land. Intex 2 brings benefits to the utility, the
house builder or developer and the consumer, in fact
everyone involved in the meter supply chain.
New simplified design that
reduces the risk of misuse or
damage on site and allows vertical
or horizontal installation for more
choice in installed location
Reduces building site damage and
associated costs by eliminating
the need for expensive street
furniture and related road and
street works liabilities
Reduces connection and total life
maintenance costs
Simplifies meter reading and levels
of service testing as well as
facilitating the potential for meter
technology upgrades
Inlet and outlet elbows rotate
through 180° to permit easier
plumbing solutions
Cartridge manifold design uses
proven stop tap technology and is
easily removed for internal
finishing
Telescopic ducting that allows
installation in standard or
extended cavity walls
Fully designed and tested to WIS
specifications
Technical data
General application
Sizes:
Connections
The Atplas Intex 2 wall mounted meter box
can be installed in any situation where a
standard underground single chamber
would be used. The Intex 2 has the added
advantage of enabling the water supply to
be connected to the new build property
at an earlier stage in its construction than
conventional chamber systems.
180° swivel connections to suit 25mm PE and
15 or 22mm copper pipes
Property wall thickness:
225 - 400mm and 30mm final internal
adjustment
Wall opening size:
230 x 150mm (nominal)1 x 2 bricks
Unit position:
Vertically or horizontally in outside wall allowing
easy access and maintenance. Minimum of
four brick courses (300mm) recommended six
brick courses (450mm) above the FFL or damp
course (which ever is higher)
Valve Type
NRV
Spares:
Technical help
For further technical data, product specifications
and general information please contact our
Customer Service Department at the telephone
number shown below.
1/4 turn
Single
Door and bezel assembly
Manifold cartridge
Connections kit
Door key
Stop valve key
Material:
Plastics:
Acetal or DMC
Tel: +44 (0)1675 437 900
e-mail: wwinfo@tyco-valves.com
Compatible Meter Listing
Minimum internal installation clearance of
270mm
Kent MSM range (Generator & Encoder)
Schlumberger P40
Socam 501LM, 610LM and 630
Sensus SRD 3
Tagus MVV 1000T
Minimum internal installation clearance of
225mm
Kent MS10
Socam 610LM
Schlumberger P40
Tagus MVV 1000T
Please note, meters are not supplied with the Intex ll unit