LT11A0 pages
Dimensions Dimensions
• Compact size : DIN standard (72 mm x 72mm / 2.83" x 2.83" W x H)
• Resolution: 1, 5, 10 ìm Selectable
• Suitable for panel mounting
• Direct interfacing from display unit to PLC or computer
• Current values, maximum, minimum, peak-to-peak values and
GO/NO GO evaluation included as standard functions.
• ADD/SUB function (2-channel model)
• Full lineup for various applications
• Compact size : DIN standard (72 mm x 72 mm / 2.83" x 2.83" W x H)
• Resolution : 5,10 ìm Selectable
• Suitable for panel mounting
• Direct interfacing from display unit to PLC or computer
• Current values, maximum, minimum, peak-to-peak values and
GO/NO GO evaluation included as standard functions.
• ADD/SUB function (2-channel model)
• Full lineup for various applications Counter unit Counter unit
Compact, lightweight,
and easy-to-mount counter.
Compact, lightweight,
and easy-to-mount counter. LT LT11A SERIES (for DT512) LT LT10A SERIES (for DT12/32)
/2.67 +0.03
+0.015
68 +1.0
+0.4
4-R1 or less
/2.67 +0.03
+0.015
68 +1.0
+0.4
68/2.67
73/2.87
68.1/2.68
74/2.91
78/3.07
88/3.46
16/0.62
1/0.03
33/1.29
60/2.36
2-R2
15/0.59
Unit : mm/inch
/2.67 +0.03
+0.015
68 +1.0
+0.4
4-R1 or less
/2.67 +0.03
+0.015
68 +1.0
+0.4
68/2.67
73/2.87
68.1/2.68
74/2.91
78/3.07
88/3.46
16/0.62
1/0.03
33/1.29
60/2.36
2-R2
15/0.59
Unit : mm/inch
Model LT11A-101 101B 101C 201 201B 201C
Common Specifications
Note 1 : I/O connector
Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only)
Output : Result evaluation (photocoupler)
Note 3 : RS-232C (8 pin mini-DIN connector)
Reset, preset value setting/recall, peak-hold start, peak-hold pause,current value hold, software version read,
comparator value setting, current value/maximum value/minimum value/peak-to-peak measuringmode selection
and output, key lock and release.
Note 2 : BCD (36 pin half-pitch connector)
Input : Reset, peak-hold start, comparator value selection (4 settings)
Output : five digits (open collector)One of current value/maximum value/minimum
value/peak-to-peakvalue selected and output.
Alarm output
Note 4 : RS-TRG pin
Trigger input for RS-232C data output
Note 5 : With measuring unit connected.
Display
Reset function
Preset function
Conparetor function
Peak hold function
Resolution
Direction
Maximum response speed
Addition and subtraction function
Alarm
Data storage
Temperature
Power consumption *5
Mass
Power voltage
Compatible measuring unit
I/O
5 digit backlit LCD, mode display
Reset key or external input (I/O connectors)
Preset value set with preset key, recalled with reset key.
Maximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input.
0.001 mm, 0.005 mm, 0.01 mm selectable
Can be switched
Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF).
Operating temperature: 0 to 40°C Storage temperature: |10 to 50°C
Resolution, direction, comparator value, preset value, modes, etc.
Power input connector (3 pins) : DC9.0 to 26.4 V.
DT512 series
Three-level comparator Comparator value set with keys on the front panel. Result evaluation: LED and I/O connector output (photocoupler)
1 channel 2 channel
„Ÿ
„Ÿ
„Ÿ
„Ÿ
100 m/min
„Ÿ
BCD sign Data signalling rate, etc. BCD sign Data signalling rate, etc.
80 m/min
A+B, A|B, B|A can be set with the direction setting.
„Ÿ
„Ÿ
›
BCD terminal RS-232C command
Recalled with BCD
reset terminal
Up to 4 values can be set for
comparator (key input).
Switched with BCD terminal.
Set or recalled with
RS-232C command
Set with RS-232C
command
Recalled with BCD
reset terminal
Set or recalled with
RS-232C command
„Ÿ
„Ÿ
Can be started with
the BCD terminal.
BCD alarm
terminal “H” (OFF)
BCD alarm
terminal “H” (OFF)
RS-232C can set
or start.
„Ÿ
„Ÿ „Ÿ „Ÿ
„Ÿ
1.8 W
Approx. 200 g
2.9 W
Approx. 230 g
2.0 W
Approx. 220 g
2.3 W
Approx. 210 g
4.0 W
Approx. 270 g
2.5 W
Approx. 230 g
„Ÿ
„Ÿ
Can be started with
the BCD terminal.
RS-232C can set
or start.
„Ÿ
„Ÿ
Up to 4 values can be set for
comparator (key input).
Switched with BCD terminal.
Set with RS-232C
command
„Ÿ
„Ÿ
BCD terminal RS-232C command
›
„Ÿ
›
›
„Ÿ
›
›
„Ÿ ›
Measuring unit input
I/O connectors *1
BCD *2
RS-232C *3
RS-TRG *4
Model LT10A-105 105B 105C 205 205B 205C
Common Specifications
Note 1 : I/O connector
Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only)
Output : Result evaluation (photocoupler)
Note 3 : RS-232C (8 pin mini-DIN connector)
Reset, preset value setting/recall, peak-hold start, peak-hold pause,current value hold, software version read,
comparator value setting, current value/maximum value/minimum value/peak-to-peak measuringmode selection
and output, key lock and release.
Note 2 : BCD (36 pin half-pitch connector)
Input : Reset, peak-hold start, comparator value selection (4 settings)
Output : five digits (open collector)One of current value/maximum value/minimum
value/peak-to-peakvalue selected and output.
Alarm output
Note 4 : RS-TRG pin
Trigger input for RS-232C data output
Note 5 : With measuring unit connected.
Display
Reset function
Preset function
Conparetor function
Peak hold function
Resolution
Direction
Maximum response speed
Addition and subtraction function
Alarm
Data storage
Temperature
Power consumption *5
Mass
Power voltage
Compatible measuring unit
I/O
5 digit backlit LCD, mode display
Reset key or external input (I/O connectors)
Preset value set with preset key, recalled with reset key.
Maximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input.
0.005 mm, 0.01 mm selectable
Can be switched
Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF).
Operating temperature: 0 to 40°C Storage temperature: |10 to 50°C
Resolution, direction, comparator value, preset value, modes, etc.
Power input connector (3 pins) : DC9.0 to 26.4 V.
DT12/32 series
Three-level comparator Comparator value set with keys on the front panel. Result evaluation: LED and I/O connector output (photocoupler)
1 channel 2 channel
„Ÿ
„Ÿ
„Ÿ
„Ÿ
100 m/min
„Ÿ
BCD sign Data signalling rate, etc. BCD sign Data signalling rate, etc.
80 m/min
A+B, A|B, B|A can be set with the direction setting.
„Ÿ
„Ÿ
›
BCD terminal RS-232C command
Recalled with BCD
reset terminal
Up to 4 values can be set for
comparator (key input).
Switched with BCD terminal.
Set or recalled with
RS-232C command
Set with RS-232C
command
Recalled with BCD
reset terminal
Set or recalled with
RS-232C command
„Ÿ
„Ÿ
Can be started with
the BCD terminal.
BCD alarm
terminal “H” (OFF)
BCD alarm
terminal “H” (OFF)
RS-232C can set
or start.
„Ÿ
„Ÿ „Ÿ „Ÿ
„Ÿ
1.8 W
Approx. 200 g
2.9 W
Approx. 230 g
2.0 W
Approx. 220 g
2.3 W
Approx. 210 g
4.0 W
Approx. 270 g
2.5 W
Approx. 230 g
„Ÿ
„Ÿ
Can be started with
the BCD terminal.
RS-232C can set
or start.
„Ÿ
„Ÿ
Up to 4 values can be set for
comparator (key input).
Switched with BCD terminal.
Set with RS-232C
command
„Ÿ
„Ÿ
BCD terminal RS-232C command
›
„Ÿ
›
›
„Ÿ
›
›
„Ÿ ›
Measuring unit input
I/O connectors *1
BCD *2
RS-232C *3
RS-TRG *4
(71.8)
2 68 68 8
68 2
BCD OUT.B
BCD OUT.A 1234
1234
BA
A+B
CPL
CPH
P-P
P-P
MIN
MAX MIN
MAX
COMP
SET
B
A
RESET
RESET MODE
72
72
(71.8)
2 68 68 8
68 2
BCD OUT.B
BCD OUT.A 1234
1234
BA
A+B
CPL
CPH
P-P
P-P
MIN
MAX MIN
MAX
COMP
SET
B
A
RESET
RESET MODE
72
72
LT11A LT10A
46 47