LY710 pages
48 49
For measurements and control in diverse field uses.
The required output board can be extended.
LY LY71
Dimensions
• Various outputs are enabled by mounting extension boards
@-BCD Output (Option)
@-Comparator Function: Relay / Open-collector (Option)
• Peak Hold Function Convenient for Statistical Measurement
• Convenient External Input Functions for Automatic Measurement
• Display Resolution Switching@• Data Storage.
• Reset/Preset/Restart@• Detecting Reference Point of Measurement Unit
• Scaling@• Flicker Control
Display
Number of input shafts
Display data
Input signal
Display resolution
Minimum input phase difference
Alarm display
Reset
Restart
Preset
Master calibration function
Datum point operations
Reference point operations
Linear compensation
Scaling
Power supply
Power consumption
Operating temperature
Storage temperature
Mass
Hold function
Measuring unit input
resolution
Specifications
Model LY71
7 digits and minus display, Color amber
1 or 2 axes (2-axis add function available; addition only is displayed when adding)
Current (1st axis, 2nd axis, addition axis), maximum, minimum and peak-to-peak values
Standard : 0.1 ìm, 0.5 ìm, 1 ìm, 5 ìm, 10 ìm, 1 s, 10 s, 1 min, 10 min
Expanded : 100 ìm, 50 ìm, 25 ìm, 20 ìm, 2 ìm, 0.05 ìm, and 1 degree can be added.
A/B quadrature signal, Z signal (Conforms to EIA-422)
Measuring unit input resolution or higher and supported inch units
Inch: Basic : 0.000005", 0.00001", 0.00005", 0.0002", 0.0005"
Inch: Expanded: 0.000002", 0.0001", 0.001", 0.002", 0.005"
100 ns
Measuring unit disconnected, Excess speed, Maximum display amount exceeded, Power failure, Error in stored data
Current value reset, Alarm cancel
Restart of peak value calculation for each axis/all axes
It is possible to store/edit up to three values for each axis.
The master calibration value is relocated when going past the reference point after the power is turned on.
It is possible to store/edit one value for each axis (when not using the master calibration function).
It is possible to store/edit one value for each axis (when not using the master calibration function).
Selectable from latch and pause
Latch : Display held while latched (Display hold)
Pause : Peak calculation stopped while paused (Peak calculation hold)
A fixed compensation amount is applied to the measuring unit's count value. Compensation amount Standard: ±600 ìm/m (Expanded: ±1000 ìm/m)
Scaling factor: 0.100000 to 9.999999
DC 12 V Rating 0.75 A Max. 1 A AC 100 V to 240 V ±10 % When using the AC adaptor PSC-22 (For U.S. only) or PSC-23 (For Europe and other countries) *Option
MAX. 32 VA connected at the AC adaptor.
0 to 40 °C (no condensation)
-20 to 60 °C (no condensation)
Approx. 1.5 kg
245
(905)
80
14
(105)
16
44
289 80
175
(1237)
07 (123)
2-M4
Max depth18
1765
1885
1985
2315
135
262
285 30
185
30
123
315 60 (315)
2-M5
Max depth7
Unit : mm/inch
• RS-232C standard function
• Peak Hold Function Convenient for Statistical Measurement
• Convenient External Input Functions for Automatic Measurement
• Display Resolution Switching
• Data Storage.
• Reset/Preset/Restart
• Detecting Reference Point of Measurement Unit
• Scaling@• Flicker Control
For measurements and control in diverse field uses.
Multifunction counter with RS-232C interface
LY LY72
Dimensions
Minimum input phase difference
Alarm display
Reset
Restart
Preset
Master calibration function
Linear compensation
Scaling
Hold function
RS-232C
Power supply
Power consumption
Operating temperature
Storage temperature
Mass
Timer
Output data selection
Datum point operations
Reference point operations
Display resolution
Input signal
Measuring unit input
resolution
Display data
Specifications by application
Display
Number of input shafts
7 digits and minus display, Color amber
1 to 3 axis
It is possible to store/edit one value for each axis (when not using the master calibration function).
It is possible to store/edit one value for each axis (when not using the master calibration function).
DC 12 V Rating 0.75 A Max. 1 A AC 100 V to 240 V ±10 % When using the AC adaptor PSC-22 (For U.S. only) or PSC-23 (For Europe and other countries) *Option
MAX. 32 VA connected at the AC adaptor.
0 to 40 °C (no condensation)
-20 to 60 °C (no condensation)
Approx. 1.5 kg
100 ns
Measuring unit disconnected, Excess speed, Maximum display amount exceeded, Power failure, Error in stored data
Current value reset, Alarm cancel
A/B quadrature signal, Z signal (Conforms to EIA-422)
Display hold
Current value
It is possible to store/edit up to three values for each axis.
A fixed compensation amount is applied to the measuring unit's count value. Compensation amount Standard: ±600 ìm/m (Expanded: ±1000 ìm/m)
Scaling factor: 0.100000 to 9.999999
Data format : All axes on same line/New line for each axis Peak-to-peak value
Transfer rate : 38400/19200/9600/4800/2400/1200 bps
Parity : None / Odd / Even
Stop bit : 1 or 2
Data length : 8 bits or 7 bits
Measuring unit input resolution or higher and supported inch units
Inch: Basic : 0.000005", 0.00001", 0.00005", 0.0002", 0.0005"
Inch: Expanded: 0.000002", 0.0001", 0.001", 0.002", 0.005"
Selectable from latch and pause
Latch : Display held while latched (Display hold)
Pause : Peak calculation stopped while paused (Peak calculation hold)
Current (1st axis, 2nd axis, addition axis), maximum,
minimum and peak-to-peak values
The master calibration value is relocated when going past the reference
point after the power is turned on.
OFF/0.2/0.5/1/5/10/30/60/300 seconds
Current value/Maximum value/Minimum value Peak-to-Peak value
Standard : 0.1 ìm, 0.5 ìm, 1 ìm, 5 ìm, 10 ìm, 1 s, 10 s, 1 min, 10 min
Expanded : 100 ìm, 50 ìm, 25 ìm, 20 ìm, 2 ìm, 0.05 ìm, and 1 degree can be added.
Current (1st axis, 3rd axis, addition axis)
—
—
—
Restart of peak value calculation for each axis/all axes
Specifications
Model LY72
Applications as gauge (set axis labels A, B, and C) Applications as scale (set axis labels X, Y, and Z)
*Please refer to LY71 panel cut-out diagram. Unit : mm/inch
44
80
245
(905)
80
1614
(105)
262±0.2
246.6+0 4–ø5.5
Mounting the counter unit from the panel front.
4–R3 or less
60 23.3
113.3+1
0
(30)
AC adaptor (option)
Counter unit Counter unit
4-M5
Max depth7
1765
1885
1985
2315
135
262
285 30
185
30
123
315 60 (315)
2-M4
Max depth18
175
289
(1237)
07 123
*Please refer to p54 for the details of the screw.
*Please refer to p54 for the details of the screw.