Pinnacles 50kV Microfocus0 pages
X-RAY
Technical Datasheet
50kV Microfocus X-ray Source
Pinnacles 50kV
Developed for applications that require high resolution over a wide-angle field of view, the
Pinnacles 50kV Microfocus X-ray source features high flux output.
Its compact design is fully radiation shielded
and insulated with an integrated high voltage
cable located on the side of the tube for easy
connection.
The Shasta µF power supply has been optimized
to power the Pinnacles 50kV Microfocus X-ray tube.
Benefits
Applications
Wide operating range enables optimal image contrast
Medical imaging
Wide field of view
Printed circuit board and electronic device inspection
Fully shielded package eliminates X-ray leakage and
Nondestructive testing of plastic, metal and mechanical
easily integrates into your system
parts
Integrated high voltage cable
Specifications
Operating voltage range:
10-50kV
Maximum power:
12W
Maximum beam current:
1.0mA
Focal spot size:
10µm (50kV, 3W) line pair resolution using JIMA RT RC-02
Focus to Object Distance (FOD):
35.18mm (1.385”)
Cone of illumination (unobstructed):
40.5° ± 0.5°
Window material and thickness:
Be, 254µm
Window diameter (unobstructed):
16.88mm (.66”)
Target material:
W
Maximum operating temperature:
50°C at potting surface
Ambient operating temperature:
0°C to 40°C; 0-95% RH up to 5,000ft
Cooling method:
Forced air @ 150cfm at 100mm (4.0”) recommended
Shielding:
Fully shielded. X-ray leakage < 1.0µSv.hr-1 at 10cm
Weight:
≈1.37kg (3 lbs)
Storage conditions:
-10°C to 55°C
Barometric Pressure: 50-106kPa; Humidity: 10-90% (no condensation)
Condensation on Be window will cause window corrosion, vacuum loss and X-ray tube failure
Shasta µF Power Supply
Industry-standard 24V Input
High voltage, cathode, and grid controls
Intuitive analog control interface
Focusing grid adjustment for optimum spot size