Neptune 5200 Series Water-Cooled Radiation Shielded X-ray Tube0 pages
X-RAY
Water-Cooled Radiation Shielded X-ray Tube
Neptune 5200 Series
Technical Datasheet
The Neptune 5200 Series is a water-cooled 50kV, 100W packaged X-ray tube designed
for applications where high flux density and continuous operation are important.
Utilizing our high stability and high intensity X-ray tube technology, the Neptune 5200 Series is ideal for most
industrial inspection and non-destructive testing applications that require high resolution, including
plastic, metal and mechanical parts inspection. Flexible and reliable, this unit is also highly
suited for use in high power XRF applications.
The 5200 Series has a brass package that features 0.2 liter/min of water flow,
which enables the unit to provide maximum X-ray shielding and heat dissipation.
The design includes high voltage, filament and water flow connectors, making it
ideal for plug and play operation.
The Neptune 5200 Series is available in wide range of targets and price points to
meet your needs.
Benefits
Applications
Wide operating range enables optimal image contrast
Stable X-ray output delivers high precision measurements
Low attenuation beryllium window ensures high
transmission of low energy x-rays
Fully-shielded compact package eliminates X-ray leakage
and easily integrates into your system
Non-destructive testing of plastic, metal and mechanical parts
Thickness gauging
Analytical XRF
Specifications
Operating Voltage Range:
Maximum Power:
Maximum Beam Current:
Maximum Filament Current:
Filament Voltage:
Target Material:
Spot Size:
Cone of Illumination:
Spot to Window Spacing (FOD):
Window Material & Thickness:
Flux & Current Stability:
Duty Cycle:
Ambient Temperature Conditions:
Humidity:
Method of Cooling:
Shielding:
Dimensions:
Weight:
10-50kV
100W
2.0mA
2.40A
3.75V (Nominal)
See Product Ordering Table
175µm where X+Y/2 and X < 210µm and Y < 210µm
25°
48.8 mm ± 1mm (1.92")
Be @ 127µm
≤ 0.2% over 4-hour period
Continuous
Operating: 0 to 40°C
Storage: -10°C to 50°C
0-95% RH up to 5,000ft
Water cooling >.21 l/min. Forced air cooling directed at the unit at 150 CFM may be
required at high power operation. Must not exceed 55°C at case surface.
0.25mR/hr @ 2" (except HV connection through HV cable)
210mm L X 106 mm W (8.25" L X 4.18" W)
6.17 kg (13.6 lbs)