Ultrabright 90kV Microfocus0 pages
X-RAY
Technical Datasheet
90kV Microfocus X-ray Source
UltraBright 96000 Series
The UltraBright Microfocus System 96000 Series is a 90kV, 80W X-ray source designed for
applications where high brightness, high magnification and small spot size are important.
Operated by an external high voltage Smart Controller capable of providing variable voltage
and power control, the UltraBright Microfocus System delivers exceptional magnification
and image quality with full control of “Brightness”. Maximum flux output is
maintained through automatic matching of a given power setting to a
corresponding optimal spot size.
Benefits
Exceptional magnification and image quality
Complete range of user control — ideal for research applications
High power operation — ideal for high flux
applications and experiments.
Compact, lightweight design — ideal for portable applications
Integrated package eliminates HV cable for
improved reliability
Applications
Product Ordering Table
Microtomography
Microfluorescence
Target Material (Part#)
Voltage
Power
Power Density
Microdiffraction
CT imaging for life sciences
and industrial inspection
W (96004)
10-90kV
10-80W
2.5W/µm
Mo (96002)
20-60kV
20-60W
1.5 W/µm
Cu (96000)
20-60kV
20-60W
1.5 W/µm
Specifications
Operating voltage range:
See product ordering table
Maximum Power:
See product ordering table
Maximum beam current:
2.0mA
Focal spot size:
13-20µm @ maximum voltage and minimum power
Focus to Object Distance (FOD):
4mm
Cone of illumination:
50° x 74° (nominal) See chart on next page
Window material and thickness:
Be, 245µm
Window diameter (unobstructed):
9.5mm (0.37”)
Window configuration
End window
Target material:
See product ordering table
Ambient operating temperature:
10°C to 40°C
Maximum operating temperature (anode):
70°C
Cooling method:
Forced air (150 CFM @ 4” recommended for continuous operation)
Shielding:
Not shielded
Dimensions:
392.4mm L x Ø114.3mm (15.5” L x Ø4.5”)
Weight:
≤ 4kg (8.81lbs.)
Storage conditions:
-10°C to 55°C
Barometric Pressure: 50-106kPa; Humidity: 10-90% (no condensation)
Condensation on Be window will cause window corrosion, vacuum loss and
X-ray tube failure.