MODEL XR1500 pages
Model XR150
X-RAY POWER SUPPLY
FEATURES
150W high voltage output
17W floating filament
Exceptionally compact size
Remote operation
Marked for EU LV Directive 2006/95/EC
EU RoHS Compliant to 2002/95/EC
High accuracy and stability
DESCRIPTION
The Series XR150 has been specifically developed for high performance
X-ray applications; the combination of surface mount, superior high
voltage stress control and packaging techniques ensures a compact
but highly reliable product. The Series XR150 is designed for use in
inspection and analytical X-ray systems with floating filament tubes.
The filament is automatically controlled by the integral beam loopcontrol and the power stage utilises a current fed resonant push-pull
converter to give high efficiency whilst ensuring reliable operation.
The Series XR150 is available with either an analogue or RS232
control interface. If the version you require is not on this datasheet
then please enquire as we produce many custom versions for specific
requirements.
SPECIFICATION
Inputs:
Input Voltage:t
Input Current:t
24VDC ±1VDC.
11A max.
Outputs:
Voltage: tt
Current: tt
Power: tt
Ripple: tt
Filament: tt
tt
0 to -60kV. Full spec applies above -3kV.
0 to -2.5mA.
Maximum output power 150W.
Less than 100V peak to peak.
0 to 3.7A (4.5V max)
Controlled by internal beam control loop.
Controls (Analogue version):
Voltage Demand:t 0 to 5VDC demands 0 to -60kV ±0.5% ±100V
Current Demand:t 0 to 5VDC demands 0 to -2.5mA ±2% ±5µA
Filament Limit:t
Internally settable between 1A and 3.7At
Controls (RS232 version):
Voltage Demand:t 12bit; 0 to FFF demands 0 to -60kV ±0.5% ±100V.
Current Demand:t 12bit; 0 to FFF demands 0 to -2.5mA ±2% ±5µA.
Filament Standby:t 12bit; 0 to FFF demands 0 to 3.7A.
Monitors (Analogue):
Output Voltage:t
0 to 5V ±0.5% ±20mV for 0 to -60kV.
Beam Current:t
0 to 5V ±2% ±20mV for 0 to -2.5mA.
Filament Current:t 0 to 5V ±5% ±20mV for 0 to 3.7A.
Filament Voltage:t 0 to 5V ±5% ±20mV for 0 to 5V.
Monitors (RS232)
Output Voltage:t
Output Current:t
Filament Current:t
Filament Voltage:t
12bit; 0 to FFF represents 0 to -60kV.
12bit; 0 to FFF represents 0 to -2.5mA.
12bit; 0 to FFF represents 0 to 3.7A.
12bit; 0 to FFF represents 0 to 5V.
Load Regulation:
Output Voltage:
Static:tt
Less than 60V no load to full load.
Dynamic:tt
Less than 3kV, recovery to within 1% of previous
setting within 200ms.
Beam Current:t
Less than ±2µA for a 10% to 100% of change of
rated load.
Line Regulation:
Output Voltage:t
Beam Current:t
Less than 60V for a 1V change in the 24V supply.
Less than ±2µA for a 1V change in the 24V supply.
Stability & Drift:
Temperature
Coefficient:t
100ppm/°C over-operating temperature range.
Drift:tt
±0.1% of rating over an 8-hour period after 30
minutes warm-up.
w w w. h i t e k p o w e r. c o m
"