Series MPI-U400 - 400W Industrial Power Supply0 pages
Series MPI-U400
400W PFC INDUSTRIAL POWER SUPPLY
FEATURES
l
Adjustable
l
400W
single output power supply
l
Active
l
High
output range
PFC meets class D
Efficiency up to 95%
l
Design
to meet IEC 60950-1, EN 60950-1,
and UL 60950-1
Utilizes
l
a thermally efficient U channel
chassis design
RoHS
l
compliant
DESCRIPTION
MPI-U400 series is a 400W single output switching power
suplly within compact size of 198x97x41mm and with active
PFC for meeting IEC 61000-3-2 and IEC 61000-3-3. It
utilizes a thermal efficient U-channel chassis design.
SPECIFICATION
Input Voltage: 90-264VAC, Continuous input range
Input Frequency: 47-63Hz, AC input
Hold up Time: Nom. 20ms;
AC 230V input, 24Vout for MPI-U405
Inrush Current: 60A
Efficiency: Max. 95%; 230VAC input, 24Vout load 14.6A
Ripple & Noise: Rated load, 20MHz bandwidth
Total Regulation: On condition of a setting output voltage,
input voltage from 90-264VAC and output from 0W to 400W.
Relative Humidity: Min. 5%RH, Max. 95%RH, noncondensing
Remote Sense: Compensates for wire voltage drop.
Short Circuit Protection: Fully protected against output
overload and short circuit. Automatic recovery upon overload
condition.
Over Voltage Protection: If for some reason the PSU fails to
control itself, built-in over voltage protection circuit will shut
down the outputs to prevent damaging external circuits.
Over Temperature Protection: When the PSU is operating
over the temperature or over load limit, the device will be
shut down automatically to protect itself.
Operating Temperature: *Min. -40 (-25) / Max. +70°C
Storage Temperature: Min. -20°C / Max. +85°C
Relative Humidity: Min. 5%RH / Max. 95%RH, non-condensing
Altitude: Operating: Max. 2K Meter, non-operating max. 4K Meter
Warranty: 12 months
Safety Approvals: IEC 60950-1, 2nd edition - CB approved
EN 60950-1, 2nd edition - CE Declaration
UL 60950-1, 2nd edition - UL approved
CSA C22.2 No. 60950-1-07, 2nd edition - cUL approved
EMI: EN 55022 - Class B; EN 61204-3 - class B,
EN 61000-3-2:2000 & EN 610003-3:2001 - class D
PFC: EN 61000-3-2:2000 & EN 610003-3:2001 - class D
EMS: IEC 61000-4-2:2001: 8kV air discharge, 6kV contact
discharge, Criteria A
IEC 61000-4-3:2002: 10V/m - Criteria A
IEC 61000-4-4:2004: 2kV line & PE - Criteria A
IEC 61000-4-5:2001: 1kV line to line, 2kV line to PE - Criteria A
IEC 61000-4-6:2004: 10V/m - Criteria A
IEC 61000-4-8:2001: 3A/m - Criteria A
IEC 61000-4-11:2004:
Voltage dips > 95%, 0.5 cycle - Criteria A
Voltage dips > 30%, 25 cycles - Criteria A
Voltage dips > 60%, 5 cycles - Criteria A
Voltage interruptions > 95%, 250 cycles - Criteria B
Note: Nominal input 230VAC and rated load would be referred to all testing
conditions if no specific condition indicated.
* can be start up at -40°C
www.hitekpower.com
"