Series AK3000 - 3000W Industrial Power Supply0 pages
Series AK3000
3000W PFC INDUSTRIAL POWER SUPPLY
FEATURES
l
Programmable output voltage (30%~105%)
l
Programmable output current (40%~105%)
l
Universal AC input / Full range
l efficiency up to 90%
High
+5V /
l 0.5A auxiliary output
High
l power density 10.8W/in³
Remote ON/OFF, remote sense function
l
Forced current sharing at parallel operation
l
Power
l OK signal
Protection: Over load, Over voltage,
l
Over temperature, Short circuit, Fan failure
SPECIFICATION
Input Voltage Range: 90~264VAC, 127-370VDC (Note 4)
Input Frequency: 47~63Hz
Power Factor: 0.98 / 230VAC; 0.99 / 115VAC at full load
Input AC Current: 36A / 115VAC; 18A / 230VAC
Inrush Current: 60A / 115VAC, 90A / 230VAC
Hold Up Time (Typ.): 16ms / 230VAC at full load
Set-up, Rise-time: 800ms, 200ms at full load
Load Regulation: ±0.5%
Line Regulation: ±0.5%
Voltage Adj. Range: ±5%
Typical Adjustment by potentiometer (VR1)
Voltage Tolerance: ±1.0% (Note 3)
Leakage Current: Less than 2.5mA / 240VAC
Hold Up Time: 16ms / 230VAC at full load
Over Load Protection: 105~110% rated output power
Protection Type: Constant current limit, Latch-style
(Recovery after reset AC power ON or inhibit).
Over Voltage Protection: Variable OVP, 120% ± 5%Vout
Protection type: Latch-style
(Recovery after reset AC power ON or inhibit).
Over Temperature Protection: 80 ±5°C.
Protection type: Shut down o/p voltage
(Recovery after reset AC power ON or inhibit).
Auxiliary Power: 5V @ 0.5A (±3%)
Remote ON/OFF:
External switch or NPN Transistor to turn ON/OFF.
Power OK Signal: Open drain signal low when PSU turns on.
Max. sink current: 20mA; Max. drain voltage: 40V
Output Voltage Trim: Adjustment of output voltage is between
30~105% of rated output.
Output Current Trim: Adjustment of output current is between
40~105% of rated output.
Parallel (Current Sharing): Please refer to page 6 (Note 5)
Working Temperature: -25 ~ +60°C (Refer to de-rating curve)
Working Humidity: 20 ~ 90% RH; non-condensing
Storage Temperature Humidity: -40 ~ +85°C, 10 ~ 95% RH
Temperature Coefficient: ±0.02% / °C (0~50°C)
Vibration: 10~500Hz, 1G 10min./1 cycle, period for 60min. each
along X, Y, Z axes. Compliance to IEC 60068-2-6-2007
Safety Standards: Certified UL 60950-1, EN 60950-1
Withstand Voltage: I/P-O/P: 3KVAC; I/P-FG: 1.5KVAC O/P-FG:
0.5KVAC
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100MOhm / 500VDC
EMI Conduction & Radiation: EN55022, EN 61000-4-4
Harmonic Current: EN61000-3-2, EN61000-3-3
EMS Immunity: EN61204-3, EN55024, EN61000-6-2,
IEC 61000-4-2, 3, 4, 5, 6, 8, 11
MTBF: 36.517K HRS Certified MIL-HDBK-217F
Cooling: Controlled by power rating & temperature
(Internal ball bearing fan)
Warranty: 24 months
www.hitekpower.com
"