PY - ITV - FLAME – T039( 2 +1)0 pages
PY-ITV-FLAME–T039(2+1)
Thin Film Pyroelectric Flame Sensor
Introduction
The Pyreos thin film pyroelectric flame sensors offer
exceptionally high responsivity, a wide field of view of
typically 100 degrees (*subject to filter band pass
specification) and class leading rapid recovery from thermal
and electrical shocks (<1 second downtime). This sensor
has excellent signal to noise at the signature 8-10 Hz flicker
range of a flame, and can provide accurate discrimination
of flame sources in triple IR flame detection systems. The
internal cmos op amp provides enhanced stability and
reliability. It has an industry standard pin-out and voltage
mode output signal.
Sensor Characteristics
Electrical Characteristics
Filter aperture
5.2 mm x 4.2 mm
Max. Voltage (+V)
8.0 V
Element size
1000 µm x 1000 µm
2.7 V
Package
TO39
Min. Voltage (+V)
Recommended Offset
V
Responsivity1
150,000 V/W
Microphonics
D*1
3.5 x 108 cm√Hz/ W
Noise 1
Mean 70 uV√Hz
Time Constant
Operating
-40 to +85 °C
Temperature
Storage Temperature
-40 to +110 °C
Op amp with 10G Ohm feedback resistor
5 standard flame types
Filter
and custom builds
Crosstalk
~<3%
Field of View
Typical 100o2
1
10Hz normalized without window and optics
2
With reference to filter used in PY0573
(+V / 2)2
S vib~2 μV/ sqrt Hz at
10Hz
~12 ms
Field of View
For V across horizontal
window aperture
For V across vertical window
aperture
For V across diagonal window
aperture
Note: Normalised polar plots show max FoV achievable along x,y axis and diagonal without any
filter applied.
Please note: the information contained in this document is subject to change without further notification. Pyreos reserves the right to alter the
performance and any resulting specification. Pyreos may choose not to supply any engineering sample devices as a commercial product. No
responsibility is accepted for any consequential loss incurred. Pyreos Ltd, SMC, West Mains Road, Edinburgh EH9 3JF, UK. Tel: +441316507009,
www.pyreos.com