Protective relay test set PW4600 pages
Optional Accessories
Current Booster (PhpcOl)
Phpc-O'
jr.,. -* ■■■
. . 7 . * ■- • • - .
• * : • •
PhpcOl current booster is designed to supply
high compliance voltage even at small current
range, suitable for testing high burden
electromagnetic current relays.
GPS synchronization (PGPS02)
• * * * — :SUH !
'GPS02 j
Is)
It provides GPS synchronization signal in PPS
(pulse per second) or PPM (pulse per minute) for
synchronized test. Trigger time can be set for end-
to-end test application.
• Circuit breaker simulator(PSSOI)
Protective Relay
Trip
Triping and Closing
Circuitry
Auxiliary triping contact
•*-
iunlary closing contact.
rTri p e
A_▼
CIRcuit breaker
Simulator
Working together with PONOVO relay testing
device, PSS01 is to be used to simulate the circuit
breaker operation for checking the relay scheme
performance. Complicated software settings can
be avoided by using this simple accessory.
Scanning Head (PACB108)
The passive optical scanning head PACB108
detects the status of an LED, that is either an
optical pulse output from an energy meter or the
binary status of a protective relay or other similar
optical source.
PowerTest Relay Test Software
Start Page
iiii,iii-i"t„,.i 11
m &1KD
3 Nrw Moduiri
s> State SBquBocrtW.ffll
j RMf>0Q
sj CB
J ton fltKbicXy Check
U QuckTtat(4V t* ■ , ■
<J OUKKtastfVL-L.I]}
t> QiKklMfPonO
J QixVletftf I Cotrell
U QuKkTm<7 V Con*)
j Tna
Differential
Differential module is suitable for use the 6 output
current channels' relay tester, which is applied on
transformer, generator and bus bar etc. differential
protection equipment test. Because of adopting the 6
currents output, it realizes the two sides three phases
test between relay tester and relay equipment.
1
Inverse time overcurrent
This module realizes the directional over-current test
and non-directional over-current test. This module also
include: testing positive sequence, negative sequence
and zero sequence instantaneous time over-current,
over-heat protection inverse time over-current or the
customized "CurrentATime" operation characteristic.
Auto-reclosing
Auto-reclosing module is the specific module which is
applied to test the reclose function. This module can
realize that relay automatic reclosing with checking the
difference between system and unit, checking the
synchronization setting, reclose set time checking and
automatic evaluating of testing results.
State Sequence
In the State-Sequence module, the relay tester can
output multiple continuous state sequences. This
module can help user to do customized test.
Ml
Power swing
Power swing module is applied to simulate the power
system swing and test the generator losing
synchronization and normal network splitting
equipment.
3
In-built analog monitoring & recording unit
This in-built analog monitoring and recording unit samples the
actual current/voltage outputs and real-time output waveform
can be displayed in the software. This makes it easy to check the
correctness of wiring before the test and observe the output
during the test process
Amplifier |
kA/ V |
In-built analog measuring and recording device |
■>■ Current output
-► Voltage output
Principle
Real-time output waveform display helps the fast trouble
shooting of wiring and test circuitry before test is actually started.
User can also use this provision to analyze the external signals,
such as phase angle, power, harmonic, etc.
IEC 61850 Function
PW460 provides analog voltage/current signal to relay and the
GOOSE message from relay is received and interpreted by relay
test equipment.
Proteetian
Relay
Real-time outputs display
i II :: i
nm
LTZDD
Ana lug Signal
l';rd-,v u-J
*■ *: 1 / J
GOOSE, IEC61B50
PONOVO Template Service
PONOVO provides relay test templates based on relay
model from different relay manufactures. With the use of
template the relay test work can be simplified greatly. Each
relay test template is one independent file which can be
opened in PowerTest relay test software. Registered users can
download the relay templates from PONOVO website. The
following are some typical relay templates for some popular
relays from relay manufactures.
ABB
LZ96
REG100
REL511
REL531
MSOC
RAZFE
REB670
REC670
REF542
REG216
REL300
REL316
REL350
REL352
REL356
REL511
REL512
REL521
REL531
REL561
REL650
REL670
RET521
RET670
REZ1
SPAC150C
SPAC310C
TPU2000R
AR EVA
CAG17
CAG37
CDD
CDG 11
CTIG
CTIGM
CTMFM
CTMM
CTNM
CTT
CTTM
CTU
DIFB
EAP3100-350
Generic Mho
KBCH
KCEU 141241
KVFG
LFZP
LFZR
LGPG
MBCH
MCGG
MFVUM
Micromho
MVAPM
MWTU
Optimho
P111
P115
P120
P121
P122
P123
P124
P125
P126
P127
P141
P142
P143
P144
P145
P241
P242
P243
P342
P343
P344
P345
P430
P437
P433
P435
P436
P438
P441
P442
P443
P444
P445
P521
P543
P544
P545
P546
P547
P631
P632
P633
P634
P642
P643
P645
P921
P922
P923
P940
P941
P942
P943
PPX
PVMM
Quadromho
SKE
SKD
VAGM22
VAPM
Schneider
& Electric
SEPAM 10
SEPAM 80
SEPAM 2000
SEPAM S42
T20
GE
Sr489
SR745
F650
SR750
GT60
D60
DLPD
G30
L90
Ge345
SEL
SEL300
SEL351
SEL587
SEL311B
SEL487B
SEL487E
SEL167
SEL411
SEL311C
SEL311L
SEL321
SEL421
SEL501
SEL587
SEL701
SEL751
SEL751A
SEL787
SIEMENS TOSHIBA
7RW600
7SA6XX
7SA511
7SA513
7SA518
7SA519
7SA522
7SD5
7SD52
7SD63
7SJ61
7SJ63
7SJ80
7SJ600
7SL24
7SS52
7ST6
7UM61
7UM62
7UM512
7UM515
7UM516
7UT6xx
7UT51
7UT512
7UT6127VE61
7VE61
7VE63
ARGUS 1
DCD121A
DCD125A
VAfYlP
VAMP 255
VAMP 265
GRB100
GRD110
GRD140
GRD150
GRF100
GRL100
GRL150
GRT100
GRZ100
Ml
PCS-902
RCS-915
RCS-931
RCS-993
RCS-902
PCS-9611
PCS-902H
PCS-931D
PCS-9611 C
WOODWARD
MRA4
MRDT4
MRI4
MRM
MRN
< > SiraNG
326GD
F_PRO
L_PRO
T_PRO
^ mi com
PCT210