Relay test set PMS601|IEC61850-8-1, IEC61850-9-1, IEC61850-9-2/LE, and IEC60044-80 pages
Intelligent substation
maintenance partner
NS601
Handheld Digital Signal Analyzer
Automatically detect IEC61850-9-1(GOOSE) message of different MAC address in the network and analyze
Stable operating environment, high reliability.
the message of the optional GOOSE control model.
7-inch TFT Color Screen
Status Indicator
Status Indicator
64-bit rubber full-function keyboard
B
uilding a strong smart grid and popularization of the
intelligent substation made secondary monitoring,
protection has undergone a historic transformation. The
change in the way of data transmission in process level has
brought new problems to test and calibration work. The
traditional instrument has not completed optical digital signal
measurements, the living construction or substation
maintenance person need a new method for optical digital
signal analysis. NS601 handheld digital signal analyzer is a
professional digital signal tools for the optical measurement,
with multi-meter, oscilloscope, harmonics analyze, phase
check, CT polarity analyze function, as well as, automatic
detection, resolve IEC61850-8-1, IEC61850 -9-1,
IEC61850-9-2/LE, IEC60044-8 format messages, It's
portable, stable and user-friendly, and also the essential tool
for intelligent substation maintenance.
IEC61850-8-1: IGoCBRef, GOOSE ID, DataSetRef,
Real-time displays GOOSE status
MAC destination address, APPID(0X), Allowed
Survival time, Commission, test, configuration
version, StNumber, SqNumber, Database Number,
VIan Sign (Priority, VID)
SD Card Slot
Charging Port
Automatically detect IEC61850-9-
USB Port (OTG)
Power Switch
1,IEC61850-9-2/LE, IEC60044-8 anddisplay
waveform, RMS value, phase
Offer history status consulting of GOOSE
2 Pair 100Mbps optical
Ethernet port(ST):1310nm wavelength,receiving
IEC61850-9-2/1 SV、GOOSE message
Optical Serial Interface:Multi-mode
Optical Fiber Port Receive FT3 Signal
Real-time displays the GOOSE deflection
Analyze message status information including:
2 group optical port
synchronization status
MU
receive signal from 2 groups MU at
Channel validation status
Automatic Analyze harmonics information
the same time
Operating and maintenance status
IEC61850-9-1、IEC61850-9-2/LE、IEC60044-8 format SV message parameters are displayed in real-time.
including:
Harmonics amplitude
comparing RMS,phase
Harmonics pase and phase
Frequency of the sample value
Portable
Stable operation
User-friendly,
SVID、 Number
IEC61850-9-1 : LDName Number of ASDU Sample
IEC61850-9-2:
of
IEC60044-8:LDName、 Sample F、 Baud Rate、
Frequency、Channel Number, Configuration
ASDU、APPID、Channel Number、MAC
Rated Phase Current、 Rated Neutral Current、
Ve r s i o n N u m b e r 、 A P P I D 、 R a t e d P h a s e
DestinationAddress、Synchronization
Rated Phase Voltage、 Rated Delay、 Channel
Current、Rated Neutral Current、Rated Phase
State、VLANMessage(Priority VID)
Number
CT polarity test