Single Phase Relay Tester T200A Brochure T 500 series0 pages
PW460 Specification
T500 Series
Universal Tester
Model T200A
Specifications
High power AC current output (I1)
Range
Accuracy
Output voltage
Power
Load time
Output
Time
0.2A~8A
1A~40A
±0.5%
40 V~ 30 V
1200VA( 40 A)
150 V~ 100 V
800VA( 8 A)
250 A
120s
100 A
750s
10~250A
10 V~8V
2000 VA(250A)
50A
<50A
3000s continuous
High power AC voltage output (U1)
Features :
Constant current design
Long output time at 250A (120s)
Can test all types high burden relay
Automatic local test modules, such as df/dt,
ramp, pick up, time, harmonic restraint
check, directional relay, etc
In-built CT test functions
Test results can be transferred to external PC
High precision AC/DC current output (I3)
Range
Accuracy
Power
Load time
Mode
AC output
0~200mA
Range
±0.5%
Accuracy
75Ω
Power(200mA)
20~100Hz
Frequency
<1A :
1~3A :
10~500V
±0.5%
1200VA(400V)
continuous
Max 60min
High power DC voltage output (Udc)
Range
Accuracy
Power (300V)
Load time Output :
Time :
10~300V
±0.5%
600W
< 1A
continuous
>1A
Max 60min
DC output
0~200mA
±0.5%
75Ω
—
Binary inputs
2
Number
30~250V DC, or dry contact
Input characteristics
±1ms ( 0.001~1s ) ±0 . 1%(1~9999.999s)
Time resolution
9999.999s
Max. measuring time
Binary output
Auxiliary DC voltage output (Aux Udc)
Range
Accuracy
Power
Load time
20~240V
± 1%
55W at 110V/110W at 220V
continuous at 0.5A
Number
Type
Break capacity AC
Break capacity DC
1
Potential free relay contacts
Vmax 250V AC / Imax 8A / Pmax 2000VA
Vmax 250V DC/ Imax 8A / Pmax 150W
Power supply
AC/DC current output (I2)
Nominal input voltage
Permissible tolerance
Nominal frequency
Permissible frequency
Mode
AC output
DC output
0~20A
0~20A
Range
±0.5%
±0.5%
Accuracy
200VA
200W
Power(20A)
20~420Hz
—
Frequency
0~360°
—
Phase angle
0.5 °
—
Phase angle accuracy
—
Distortion 1A~20A <0.5%
500μs
500μs
Transient response
60s
Load time 20A :
240s
10A :
continuous
<10A :
1%
Harmonic(2nd,3rd,5th,7th)accuracy
Range
Accuracy
AC/DC voltage output (U2)
EMC (Emission)
EMC (Immunity)
Safety
110/220Vac
-20% ~+15%
50/60Hz
45~65Hz
Voltmeter
0~600V AC/DC
± 1%
Ammeter
Range
Accuracy
0~6A AC/DC
±1%
Certificates
www.ponovo.com.cn
Mode
AC output
0~120V
Range
±0.5%
Accuracy
60VA
Power(120V)
20~100Hz
Frequency
0~360°
Phase angle
0.5 °
Phase angle accuracy
<0.5%
Distortion 5V~120V
500μs
Transient response
DC output
0~120V
±0.5%
60W
—
—
—
—
500μs
IEC-61000-3-2/3
IEC 61000-4-2/3/4/5/6/11
IEC 61010-1
Others
Operation temperature
Operation humidity
Weight
Dimensions (W x H x D)
PC connection
Ground Socket (earth)
-5 ~ +50°C
5 ~95 %, non-condensing
20.7kg
430 mm×250mm×250 mm
USB
4 mm banana socket; front side