R15I-AST0 pages
R15I-AST Sensor
Integral Preamplifier
Acoustic Emission Sensor
Description and Features
Operating Specifications
PAC’s integral preamp sensors were specifically engineered
to attain high sensitivity and have the capability to drive
long cables without the need for a separate preamplifier.
Incorporating a low-noise input, 40 dB preamplifier and a
filter all inside the sensor housing, these transducers are
completely enclosed in metal stainless steel (or aluminum)
housings that are treated to minimize RFI/EMI interference.
Care has also been taken to thermally isolate the critical
input stage of the preamplifier in order to provide excellent
temperature stability over the range of -35º to 75º C.
t Dynamict
t
Peak Sensitivity, Ref V/(m/s).................... 109 dB
t Environmental
t
Temperature Range.......................... -35 to 75ºC
Their integrated Auto Sensor Test (AST*) capability allows
these sensors to pulse as well as receive. This feature lets
you verify the sensor coupling and performance at any time
Shock Limit........................................... 500 g
Completely shielded crystal for maximum RFI/EMI
immunity
throughout the test.
Applications
This general purpose sensor provides a good mix of high
sensitivity and high low frequency rejection. These properties make it very useful for monitoring common structures
such as pipelines, vessels, bridges, and storage tanks in
petroleum, refineries, chemical plants, offshore platforms,
as well as factory and process monitoring applications. It is
PAC’s most popular and highest volume selling sensor.
Peak Sensitivity, Ref V/µbar...................... -22 dB
Operating Frequency Range................ 80-200 kHz
Resonant Frequency, Ref V/(m/s). ............. 75 kHz
.
Resonant Frequency, Ref V/µbar............... 150 kHz
Directionality. .................................. +/-1.5 dB
.
t Physical
t
Dimensions. .................. 1.13” diameter x 1.23” h
.
t
................................................(29 x 31 mm)
t
Weight. ...................................................70
.
Case Material. ..................... Stainless Steel (304)
.
Face Material. ....................................Ceramic
.
Connector. .............................................BNC
.
Connector Locations..................................Side
Ordering Information and Accessories
R15I....................................................... R15I-AST
Cable (specify cable length)...........................1234 - X
Magnetic Hold-Down . ...................................MHR15I
.
Amplifier......................................................AE2A
Sensors include
NIST Calibration Certificate & Warranty
TIFIED Q
U
GE
M
Due to continuing improvement, MISTRAS Group, Inc. reserves the right to amend specifications without notice.
Copyright © 2010 MISTRAS Group, Inc. All Rights Reserved.
MANA
ER
Fax: 609-716-0706
TY
T S YS T E
Phone: 609-716-4000
Email: sales.systems@mistrasgroup.com www.mistrasgroup.com
LI
EN
Products & Systems
Division
A
M
195 Clarksville Road, Princeton Junction, NJ 08550
C
Frequency response of the R15I-AST. Calibration based on ASTM
E1106; Calibration based on ASTM E976.
* AST — Auto Sensor Testing feature allows AE systems to control the sensor as a pulser
and a receiver at the same time. It can therefore characterize its own condition as well
as send out a simulated acoustic emission wave that other sensors can detect, so the
condition of the nearby sensors also can be tested.
ISO 9001