CH15I0 pages
CH15I Sensor
Medium Frequency & Low Noise
Integral Preamp Acoustic Emission Sensor
Description and Features
Operating Specifications
The CH15I sensor is a medium frequency, resonant, acoustic
t Dynamict
emission sensor with an integral, low noise, filtered, 40 dB
preamplifier that can drive up to 1000 feet of cable. The
sensor comes standard with PAC’s unique “Auto Sensor Test”
Peak Sensitivity, Ref V/(m/s); Ref [V/µbar].............109 [-22] dB
Operating Frequency Range. ............................ 100 – 200 kHz
.
Resonant Frequency Ref V/(m/s); Ref [V/µbar]....... 75 [150] kHz
Directionality. .................................................... ±1.5 dB
.
t Electrical
(AST*) function.
The CH15I features a strong, insulated, lightweight, aluminum alloy, integrated body structure that is color-coded blue
to identify the sensor model. This sensor’s outside shell is
anodized, providing a nonconductive finish to prevent any
possible electric shorts from metal testing structures. It
is the same size and has the same frequency response and
sensitivity as the R15I sensor, but the EMI shielding ability of
the CH15I has been improved by more than 300% compared
with previous versions.
Applications
t
Metalst
t
Cranes
t
Compressed gas cylinderst
Gain.
...................................................................40 dB
Power Requirements..............................16 - 30 Vdc @ 25 mA
Dynamic Range..................................................... >80 dB
Output Voltage....................................... 20 V peak to peak
Noise Level (RMS rti)............................................. <2.4 µV
Output Drive Impedance. ...........................................50 Ω
.
Sensor Drive Capability......................... up to 1000 ft (300 m)
AST Pulse. .......................... 24 V, 3 microseconds into crystal
.
Grounding................Case grounded, isolated from sensing face
t Environmental
t
t
t
Temperature Range. ......................................... -35 to 75ºC
.
Shock Limit........................................................... 500 g
Completely enclosed crystal for RFI/EMI immunity
t Physical
t
Pressure vessels
t
Bucket truckst
t
Structures
Dimensions. ......................1.13” dia x 1.28” h (29 x 32.6 mm)
.
Weight............................................................ 51 grams
Case Material................... Blue color, anodized aluminum alloy
Face Material..................................................... Ceramic
Connector.............................................................. BNC
Connector Locations................................................. Side
Seal................................................................... Epoxy
Matching Cable. ................................................... 1234-X
.
Ordering Information and Accessories
Cable (specify cable length).............................................1234 - X
Magnetic Hold-Down . .................................................... MHR15I
.
Amplifier....................................................................... AE2A
Sensors include
NIST Calibration Certificate, Auto Sensor Test Function & Warranty
TIFIED Q
U
GE
M
Due to continuing improvement, MISTRAS Group, Inc. reserves the right to amend specifications without notice.
Copyright © 2010 MISTRAS Group Inc. All Rights Reserved.
MANA
ER
Fax: 609-716-0706
TY
T S YS T E
Phone: 609-716-4000
Email: sales.systems@mistrasgroup.com www.mistrasgroup.com
LI
EN
Products & Systems
Division
A
M
195 Clarksville Road, Princeton Junction, NJ 08550
C
Frequency response of the CH15I. Calibration based on ASTM
E1106; Calibration based on ASTM E976.
* AST — Auto Sensor Testing feature allows AE systems to control the sensor as a pulser
and a receiver at the same time. It can therefore characterize its own condition as well
as send out a simulated acoustic emission wave that other sensors can detect, so the
condition of the nearby sensors also can be tested.
ISO 9001
R#117403
"