4-Axis Protein Crystallography System0 pages
True Nano™
4-Axis Protein Crystallography System
ALIO’s integrated 4-axis system was specifically developed to help front line
scientists to conduct industry leading x-ray research in protein crystallography.
ALIO True Nano™ Specifications
System Run-Out at XY
Z
AI-LM-20000
Radial: < +/- 1um T.I.R.
Axial: < +/- 100nm T.I.R.
Bottom Axis
Travel
Resolution
4.88nm
Repeatability
< ± 100nm
Step Size
R
100mm
20nm to 50nm
AI-TM-183R
Mounted on Z
Travel
Resolution
0.02 arc-sec
Repeatability
± 0.2 arc-sec
Speed, min
XY
360° Continuous
0.3 arc-sec/sec
AI-D4-2500E
AI-D2-1200E
Mount to the Face
of the Rotary
Travel
10mm
Resolution
4.88nm
Repeatability
± 200nm to ± 300mm
Step Size
20nm to 50nm
Integrated 4-Axis Controller
EPICS Compatible
110V or 220V Compatible
Options:
ALIO True Nano™
NIST Traceable Proof
Granite Base for Improved Vibration Isolation
Sample Holder
Eight of the world's largest pharmaceutical companies have banded together to run a beam-line at Argonne's Advanced Photon
Source (APS) dedicated to determining protein structures and developing new drugs. The discoveries that they and other
biomedical researchers at the APS make today provide the foundation for life-saving drugs that doctors will prescribe tomorrow.
The X-rays produced by the APS synchrotron and shot through IMCA's beam-lines allow the researchers at these companies to
scan thousands of proteins and inhibitor molecules for the next wonder drug.
(source: http://www.anl.gov/Media_Center/ArgonneNow/Winter_2009/pharmaceuticals.html)
ALIO’s passion has built a reputation for unmatched quality and performance with our nano-precision motion systems.
ALIO’s world leading performance is backed by our NIST referenced ML10 laser interferometer system from Renishaw.
ALIO True Nano™ means Proof.
16-October 2009
v3
"