4452690 pages
UNI096-5, UNI048-5
Programmable PC/104 I/O Card
Features
■ 96/48 digital/frequency I/O channels programmable
in any combination
■ Compatibility with digital/analog opto-isolated
modules Opto-22, Grayhill (including 73G, 73L)
■ Frequency, phase measurement at any channel
■ Timers/counters
■ Frequency generation and pulse width modulation (PWM)
at any channel
■ Code conversion at any channel
■ Timing diagrams generation
■ Input event interrupts generation
■ Programmable debounce logic
■ In-System Programming
■ Extended operating temperature range from -40°C to +85 °C
Description
The UNI096/48-5 are 96/48-channel
digital I/O PC/104 add-on cards. The
cards deal with the TTL-level signals
and can be used to interface with opto-
isolated modules racks, displays, LED-
devices. The card provides a wide range
of functions - counting, sequencing,
timing diagrams generation, pulse width
modulation, code conversion etc.
The module uses FPGA chips for
signal processing. It supports in-system
programming which allows to change
the control logic algorithm without
turning power off. Software examples
are available in C, description files of
basic and custom circuit programming
variants are available on the CD supplied
with the card or can be downloaded via
Internet from the Fastwel web-site:
http://www.fastwel.com.
Interface with Grayhill opto-isolated
modules (circuit versions "gOO", "g01 "j
One of the main applications of the
UNI096/48 is an interface with opto-
isolated Opto-22 and Grayhill modules
and with isolated digital I/O cards (TBI-
24/0, TBI-0/24). These versions of the
circuit allow to operate with opto-
isolation modules of any type (analog,
digital, input, output) through any of
96/48 channels. When operating with
Gray-hill analog opto-isolated modu-
les the UNI096-5 accepts four
input/output lines of series 73G or eight
in-put/output lines of series 73L
simultaneously without using the
processor.
The interrupts generation is available
while operating with the analog opto-
isolated modules.
Displays control
The UNI096/48-5 can be used to
interface with LCD, vacuum fluorescent
displays or LED indicators with parallel
and serial interfaces.
Counters/timers
The UNI096/48-5 can be used as
timers or pulse counters. Circuit version
"tOO" provides 16/8 16-bit timers based
on external or internal frequency
source. Circuit versi-on "cOO" provides
96/48 16-bit counters.
Frequency measurement
Frequency measurement is one of
popular applications of UNI096/48-5
card. There are different types of
frequency measurement circuits in the
basic circuitry set. They differ by:
measurement methods (averaging for
time period, filling by the sample
frequency); measurement ranges (from
0.001 Hz to 50 MHz); accuracy (up to
0.0001 %), and the number of measuring
devices (for UNI096-5 - from 4 to
32 devices). Frequency measurement
can be performed at any channel of the
card. The frequency gauges can
generate interrupts (AND/OR) both
within card and from several cards.
Pulse width modulation and
frequency generation
The UNI096/48-5 can be used for
frequency generation and PWM in
frequency range up to 25 MHz.
Corporate Offices
FASTWEL GROUP CO. LU
108 Profsoyuznaya str.
Moscow, Russia 117437
Tel: +7 (495) 232-1681
Fax:+7 (495) 232-1654
E-mail: info@fastwel.com
Web: www.fastwel.com
FASTWEL Corporation US
55 Washington street, Suite 310
Brooklyn, NY 11201
Tel: 1.718.554.3686
Fax: 1.718.797.0600
Toll free: 1.877.787.8443
(1.877.RURUGGED)
E-mail: lnfo@fastwel.com
FASTWEL Asia
6F., No. 118, Ln.235, Baoqlao
Rd., Xlndlan Dlst,
New Taipei City, Taiwan, R O C.
Tel:+886-2-8912 1938
Fax: +886-2-8912 1939
E-mail: asia@fastwel.com
"