CX LT0 pages
-^optris
nnnnoptris® CX
nnnnTwo wire infrared sensor for
nnnnrugged industrial applications
nnnnFEATURES
nnnn- Easy two wire installation
nnnn- Wide measurement range of -30 °C to 900 °C
nnnn- Optional USB programming interface and software
nnnn- Wide power range: 5 - 30 V DC
nnnn- Optical resolution of 22:1
nnnn- Simultaneous two wire output and digital
nnnncommunication
nnnn- Alarm output (0 - 30 V/ 500 mA)
nnnnGeneral specifications | |
Environmental rating | IP 65 (NEMA-4) |
Ambient temperature | -20 - 75° C |
Storage temperature | sensing head: -40 - 85°C |
Relative humidity | 10 - 95%, non condensing |
Vibration | IEC 68-2-6: 3 G, 11 - 200 Hz, any axis |
Shock | IEC 68-2-27: 50 G, 11 ms, any axis |
Weight | 350 g |
Electrical specifications | |
Output /analog | 4 - 20 mA |
Output / alarm | 0- 30 V/500 mA (open collector) |
Outputs/digital (optional) | USB |
Loop impedance | max. 1000n 1> |
Cable length | 8m |
Power supply | 5-30 V DC |
1) in dependence on supply voltage |
Measurement specifications | |
Temperature range (scalable via software) | -30 - 900°C |
Spectral range | 8- 14/jm |
Optical resolution (90% energy) | 22:1 |
CF-0ptics (optional) | 0.6 mm @ 10 mm |
System accuracy (at ambient temperature 23 ±5°C) | ±1% or±1,4°C1 |
Repeatability (at ambient temperature 23 ±5°C) | ±0.5% or±0.7°C1 |
Temperature resolution | 0.1°C |
Response time (95%) | 150 ms |
Emissivity/Amplification (adjustable via software) | 0.100-1.100 |
Transmissivity (adjustable via software) | 0.100-1.100 |
Signal processing (parameter adjustable only via optional software) | peak hold, valley hold, average; extended hold function with threshold and hysteresis |
1 whichever is greater
"