optris CTlaser 05M0 pages
optris® CTlaser 05M
FEATURES
Precise non-contact temperature measurement
of liquid metals from 1000°C to 2000°C
JJ
JJ
JJ
JJ
JJ
JJ
JJ
General Specifications
Accurate temperature measurements of liquid
metals
Short measuring wavelength of 525 nm minimizes
errors due to emissivity uncertainty and
atmospheric vapour effects
Temperature range from 1000°C to 2000°C,
measuring spots up from 1 mm and response
time of 1 ms
Usable up to 85°C ambient temperature without
cooling and automatic laser switch off at 50°C
Industrial accessories available
Optical resolution up to 150:1 with selectable focus
Double laser aiming marks real spot location at
any distance
Measurement Specifications
Environmental rating
Ambient temperature
Temperature range
(scalable via programming
keys or software)
Sensing head: -20°C to 85°C (50°C
with laser ON)
Electronics: -20°C to 85°C
1000°C to 2000°C
Spectral range
IP 65 (NEMA-4)
525 nm
Storage temperature
Sensing head: -40°C to 85°C
Electronics: -40°C to 85°C
Optical resolution
(90% energy)
150:1
Relative humidity
10 - 95%, non-condensing
Vibration (sensor)
IEC 68-2-6: 3 G, 11-200 Hz,
any axis
System accuracy1)
(at ambient temp. 23 ±5°C)
± 1% of reading (≤ 1100°C)
± (0.3% of reading + 2°C) (> 1100°C)
± 0.5% of reading (≤ 1100°C)
Shock (sensor)
IEC 68-2-27: 50 G, 11 ms, any axis
Repeatability
(at ambient temp. 23 ±5°C)
Weight
600 g (sensing head)
420 g (electronics)
Temperature resolution
0.2 K
Exposure time
1 ms (90 %)
Emissivity/Gain
(adjustable via programming
keys or software)
0.100 - 1.100
Transmissivity/Gain
(adjustable via programming
keys or software)
0.100 - 1.100
Signal processing
(parameter adjustable via
programming keys or
software, respectively)
peak hold, valley hold, average;
extended hold function with
threshold and hysteresis
Software
optris Compact Connect
2)
Electrical Specifications
Outputs/analog
0/4 - 20 mA, 0-5/10 V, thermocouple
J, K
Alarm output
24 V/50 mA (open collector)
Optional
relay: 2 x 60 V DC/42 V ACeff; 0.4 A;
optically isolated
Outputs/digital (optional)
USB, RS232, RS485, CAN,
Profibus DP, Ethernet
Output impedances
mA max. 500 Ω (with 8-36 V DC)
mV min. 100 kΩ load impedance
thermocouple 20 Ω
Inputs
Programmable functional inputs
for external emissivity adjustment,
ambient temperature compensation,
trigger (reset of hold functions)
Cable length
3 m (standard), 8 m, 15 m
Current draw
max. 160 mA
Power Supply
8-36 V DC
Laser 635 nm
± (0.1% of reading + 1°C) (> 1100°C)
1mW, ON/OFF via electronic box or
software
1)
2)
ε = 1, exposure time 1 s
with dynamic adaptation at low signal levels
Innovative Infrared Technology
"