ct 2m0 pages
-d^optris
nnnnI infrared thermometer!
nnnnoptnis®
nnnnPrecise non-contact temperature measurement
nnnnfrom 250°C to 2200°C
nnnn■ Miniaturized Infrared Thermometer with 1.0 urn
nnnnrespectively 1.6 urn wave length range for
nnnnmeasurements of metals, of secondary metal
nnnnprocessing, metal oxides and ceramic materials
nnnn■ Very small sensing head of 14 mm diameter and
nnnn28 mm length fits everywhere and is usable up to
nnnn125°C ambient temperature without cooling
nnnn■ Temperature ranges from 250°C to 2200°C,
nnnnmeasuring spots up from 1.8 mm and exposure
nnnntimes up from 1 ms
nnnn■ Short measuring wave length of 1.0 urn
nnnnrespectively 1.6 urn reduces error of temperature
nnnnreadings on surfaces with low or unknown
nnnnemissivity
nnnnEnvironmental rating | IP 65 (NEMA-4) |
Ambient temperature | Sensing head: -20°C to 100°C (1M) to 125°C (2M) Electronics: -20°C to 85°C |
Storage temperature | Sensing head: -40°C to 100°C (1M) to 125°C (2M) Electronics: -40°C to 85°C |
Relative humidity | 10 - 95%, non condensing |
Vibration (sensor) | IEC 68-2-6: 3 G, 11-200 Hz, any axis |
Shock (sensor) | IEC 68-2-27: 50 G, 11 ms, any axis |
Weight | Sensind head: 40 g Electronics: 420 g |
Outputs/analog | 0/4 - 20 mA, 0-5/10 V, thermocouple J, K, alarm |
Alarm output | 24 V/50 mA (open collector) |
Optional | relay: 2 x 60 V DC/42 VACelî; 0.4 A; optically isolated |
Outputs/digital (optional) | USB, RS232, RS485, CAN, Profibus DP, Ethernet |
Output impedances | mA max. 500 Q. (with 8-36 V DC) mV min. 100 kO load impedance thermocouple 20 0 |
Inputs | programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions) |
Cable length | 3 m (standard), 8 m, 15 m |
Current draw | max. 100 mA |
Power Supply | 8-36 V DC |
Temperature ranges (scalable via programming keys or software) | 485°Cto 1050°C (1 ML) 650°Cto 1800°C (1MH) 800°Cto 2200-C (1MH1) 250°C to 800°C (2ML) 385°Cto 1600°C (2MH) 490°Cto 2000°C (2MH1) |
Spectral ranges | 1.0 urn (1M)/1.6 urn (2M) |
Optical resolution CT 1ML/2ML (90% energy) | 40:1 (2.7 mm @ 110 mm) |
Optical resolution CT 1MH/1MH1/2MH/2MH1 (90% energy) | 75:1 (1.5 mm @110 mm) |
System accuracy11 (at ambient temp. 23 ±5°C) | ± (0.3% of reading + 2°C) |
Repeatability (at ambient temp. 23 ±5°C) | ± (0.1% of reading + 1°C) |
Temperature resolution | 0.1 K |
Exposure time2' | 1 ms (90 %) |
Emissivity/Gain (adjustable via programming keys or software) | 0.100-1.100 |
Tra nsm issi vity/Ga in (adjustable via programming keys or software) | 0.100-1.100 |
Signal processing (parameter adjustable via programming keys or software, respectively) | peak hold, valley hold, average; extended hold function with threshold and hysteresis |
Software | optris Compact Connect |
1> £ = 1, Exposure time 1 s
nnnn21 with dynamic adaptation at low signal levels
"