optris CTlaser 1M / 2M0 pages
optris® CTlaser 1M/2M
FEATURES
Precise non-contact temperature measurement
with precise aiming from 250°C to 2200°C
Accurate temperature measurements of metals,
secondary metal processing and ceramic materials
Double laser aiming marks real spot location at any
distance
Optical resolution up to 300:1 with selectable focus
T
Temperature ranges from 250°C to 2200°C,
measuring spots up from 0,45 mm and response
times up from 1 ms
Usable up to 85°C ambient temperature without
cooling and automatic laser switch off at 50°C
Short measuring wavelength of 1 μm or 1.6 μm
General Specications
Measurement Specications
Storage temperature
Repeatability
(at ambient temp. 23 ±5°C)
± (0.1% of reading + 1°C)
Temperature resolution
0.1 K (1ML, 2ML)
0.2 K (1MH, 1MH1, 2MH, 2MH1)
1 ms (90 %)
Emissivity/Gain
(adjustable via programming
keys or software)
0.100 - 1.100
Transmissivity/Gain
(adjustable via programming
keys or software)
0.100 - 1.100
Signal processing
(parameter adjustable via
programming keys or
software, respectively)
peak hold, valley hold, average;
extended hold function with threshold
and hysteresis
Software
Sensind head: 40 g
Electronics: 420 g
± (0.3% of reading + 2°C)
optris Compact Connect
IEC 68-2-27: 50 G, 11 ms,
any axis
Weight
System accuracy1)
(at ambient temp. 23 ±5°C)
IEC 68-2-6: 3 G, 11-200 Hz,
any axis
Shock (sensor)
150:1 (1ML, 2ML)
300:1 (1MH, 1MH1, 2MH, 2MH1)
10 - 95%, non condensing
Vibration (sensor)
1.0 μm (1M)/1,6 μm (2M)
Sensing head: -40°C to 85°C
Electronics: -40°C to 85°C
Relative humidity
Optical resolution
(90% energy)
Sensing head: -20°C to 85°C (50°C
with laser ON)
Electronics: -20°C to 85°C
485°C to 1050°C (1ML)
650°C to 1800°C (1MH)
800°C to 2200°C (1MH1)
250°C to 800°C (2ML)
385°C to 1600°C (2MH)
490°C to 2000°C (2MH1)
Spectral ranges
IP 65 (NEMA-4)
Ambient temperature
Temperature ranges
(scalable via programming keys
or software)
Exposure time2)
Environmental rating
Electrical Specications
Outputs/analog
0/4 - 20 mA, 0-5/10 V, thermocouple
J, K
Alarm output
24 V/50 mA (open collector)
Optional
relay: 2 x 60 V DC/42 V ACeff; 0.4 A;
optically isolated
Outputs/digital (optional)
USB, RS232, RS485, CAN,
Probus DP, Ethernet
Output impedances
mA max. 500 Ω (with 8-36 V DC)
mV min. 100 kΩ load impedance
thermocouple 20 Ω
Inputs
programmable functional inputs for
external emissivity adjustment, ambient
temperature compensation, trigger
(reset of hold functions)
Cable length
8-36 V DC
Laser 635 nm
Ɛ = 1, Exposure time 1 s
with dynamic adaptation at low signal levels
max. 160 mA
Power Supply
2)
3 m (standard), 8 m, 15 m
Current draw
1)
1mW, ON/OFF via electronic box or
software
Innovative Infrared Technology
"