ct g50 pages
-^optris
nnnnoptris" CT G5
nnnnPrecise noncontact temperature measurement
nnnnof glass from 100 to 1650°C
nnnnFEATURES
nnnn- Accurate temperature measurement of flat glass,
nnnncontainer glass, light bulb manufacturing, car glass
nnnnproduction and manufacturing of photovoltaic cells from
nnnn100°C to 1650°C
nnnn- Applicable up to 85°C ambient temperature without
nnnncooling
nnnnGeneral specifications
nnnnEnvironmental rating
nnnnAmbient temperature
nnnnStorage temperature
nnnnRelative humidity
nnnnVibration (sensor)
nnnnShock (sensor)
nnnnWeight
nnnnIP 65 (NEMA-4)
nnnnsensing head: -20 - 85°C
nnnnelectronics: 0 - 85°C
nnnnsensing head: -40 - 85°C
nnnnelectronics: -40 - 85°C
nnnn10 - 95%, non condensing
nnnnIEC 68-2-6: 3 G, 11 - 200 Hz, any axis
nnnnIEC 68-2-27: 50 G, 11 ms, any axis
nnnnsensing head 42 g
nnnnelectronics 420 g
nnnnElectrical specifications
nnnnOutputs/analog
nnnnAlarm output
nnnnOptional
nnnnOutputs/digital (optional)
nnnnchannel 1: 0/4-20 mA, 0- 5/10 V,
nnnnthermocouple J, K
nnnnchannel 2: sensing head temperature (-20 ■
nnnn85°C as 0 - 5 V or 0 -10 V), alarm output
nnnnOpen - collector (24V / 5mA)
nnnnrelay: 2 x 60 V DC/42 V ACeff ; 0.4 A; optically
nnnnIsolated
nnnnUSB, RS232, RS485 (optional), CAN-Bus,
nnnnProfibus DP, Ethernet
nnnnOutput impedances
nnnnmA max. 500 a (with 8 - 36 V DC)
nnnnmV min. 100 ka load impedance
nnnnthermocouple 20a | |
Inputs | programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger |
Cable length | 3 m (standard), 8 m, 15 m |
Current draw | max. 100 mA |
Power supply | 8 - 36 V DC |
Measurement specifications | |
Temperature range (scalable via programming keys or software) | 100°C - 1200°C (G5L) |
250°C - 1650°C (G5H) | |
Spectral range | 5.2pm |
Optical resolution (90 % Energy) | 10:1 (G5L) |
20:1 (G5H) | |
System accuracy (at ambient temperature 23 ±5°C) | ±1% or±2°C1 |
Repeatability (at ambient temperature 23 ±5°C) | ±0.5% or ±0.5°C1 |
Temperature resolution (NETD) | O.rC (G5L) /0.2°C (G5H) |
Response time (90 % Signal) | 80 ms (G5H)/120ms(G5L) |
Emissivity/Gain (adjustable via programming keys or software) | 0.100-1.100 |
Transmissivity/Gain (adjustable via programming keys or software) | 0.100-1.100 |
Signal processing (parameter adjustable via programming keys or software, respectively) | peak hold, valley hold, average; extended hold function with threshold and hysteresis |
whichever is greater
"