optris CSvideo 2M0 pages
optris® CSvideo 2M
FEATURES
Two-wire infrared thermometer for temperature
measurement of metals from 250°C to 1600°C
with video sighting and precise laser aiming
JJ
JJ
JJ
JJ
JJ
JJ
General specifications
Parallel use of video sighting and double laser
aiming for easy sensor alignment (measuring
spots up from 0.5 mm) under all viewing conditions
possible
Accurate temperature measurements of metals,
secondary metal processing and ceramic materials
(250° C to 1600°C)
Response times up from 10 ms
Standard two-wire interface for reliable data
transfer and easy integration into a PLC
Usable up to 70°C ambient temperature without
cooling
optris Compact Connect software for fast on-site
sensor setup, video alignment and real-time process monitoring
Measurement specifications
Environmental rating
IP 65 (NEMA-4) front mountable
at vacuum processes (up to
10-3 mbar)
Temperature range
(scalable via software)
250°C to 800°C (2ML)
385°C to 1600°C (2MH)
Ambient temperature
-20°C to 70°C
(50°C with laser ON)
Spectral range
1.6 μm
Optical resolution
(90 % energy)
150:1 (2ML)
300:1 (2MH)
Storage temperature
-40°C to 85°C
Relative humidity
System accuracy
(at Tamb = 23 ± 5°C)
± (0,3% of reading + 2°C)
10-95%, non-condensing
Vibration
IEC 68-2-6: 3 G, 11-200 Hz,
any axis
Repeatability
(at Tamb = 23 ± 5°C)
± (0,1% of reading + 1°C)
Shock
IEC 68-2-27: 50 G, 11 ms,
any axis
Temperature resolution
0.1 K
600 g
Response time
(90% signal)
10 ms
Weight
Emissivity/ Gain
(adjustable via
0.100 - 1.100
IR window correction
(adjustable via software)
0.100 - 1.000
Signal processing
(parameter adjustable via
software)
peak hold, valley hold, average;
extended hold function with
threshold and hysteresis
Software (incl.)
optris Compact Connect (Sensor
setup, video sighting and process monitoring)
Electrical specifications
Output / analog
4-20 mA
Loop resistance
max. 1000 Ω1)
Output / alarm
0-30 V / 500 mA
(open-collector)
Output/ digital
USB 2.0
Video sighting2)
digital (USB 2.0), 640 x 480 px,
FOV 3.1° x 2.4°
Cable length
(analog + alarm)
3 m, 8 m, 15 m
Cable length (USB)
In dependence on supply voltage
Video sighting is usable at focus distance
(± 10% of measuring distance)
45 mA at 5 V
20 mA at 12 V
12 mA at 24 V
Power supply
2)
5 m (incl.), 10 m, 20 m,
100 m (over Ethernet)
Current draw (laser)
1)
5-28 V DC
Innovative Infrared Technology
"