optris CT XL 3M0 pages
optris® CT XL 3MH
FEATURES
Non-contact temperature measurement from
100°C to 1800°C of laser material processing
New infrared thermometer for laser material
processing, laser welding and laser soldering
Special blocking filter against laser radiation of
most of all diode lasers and solid state lasers
(VIS to 1800 nm and 10.6 µm)
Far focus version for use with laser collimator
optics
Usable up to 85°C ambient temperature without
cooling
Short wave length range of 2.3 µm to reduce error
of reading with measurements on materials with
unknown emissivity
General Specifications
Environmental rating
Measurement Specifications
IP 65 (NEMA-4)
Temperature ranges1)
(scalable via programming
keys or software)
100°C to 600°C (3MH)
150°C to 1000°C (3MH1)
200°C to 1500°C (3MH2)
250°C to 1800°C (3MH3)
Spectral ranges
2.3 μm
Ambient temperature
-40°C to 85°C (sensing head)
0°C to 85 (electronics)
Storage temperature
-40 to 125°C (sensing head)
-40°C to 85°C (electronics)
Relative humidity
10 - 95%, non condensing
Optical resolution
(90 % energy)
100:1 (3MH)
300:1 (3MH1-H3)
Vibration (sensor)
IEC 68-2-6: 3 G, 11-200 Hz,
any axis
System accuracy2)
(at ambient temp. 23 ± 5°C)
± (0.3% of reading + 2°C)
Shock (sensor)
IEC 68-2-27: 50 G, 11 ms,
any axis
Repeatability
(at ambient temp. 23 ± 5°C)
± (0.1% of reading + 1°C)
Weight
150 g (sensing head)
420 g (electronics)
Temperature resolution
0.1 K
Exposure time3) (90% signal)
1 ms
Emissivity/Gain
(adjustable via programming
keys or software)
0.100 - 1.100
Transmissivity/Gain
(adjustable via programming
keys or software)
0.100 - 1.100
Signal processing
(parameter adjustable via
programming keys or software, respectively)
peak hold, valley hold, average;
extended hold function with
threshold and hysteresis
Software
optris Compact Connect
Electrical Specifications
Outputs/analog
0/4 - 20 mA, 0-5/10 V, thermocouple
J, K, alarm
Output/alarm
24 V/50 mA (open collector)
Optional
relay: 2 x 60 V DC/42 V ACeff; 0.4 A;
optically isolated
Outputs/digital (optional)
USB, RS232, RS485, CAN, Profibus
DP, Ethernet
Output impedances
mA max. 500 Ώ (with 8-36 V DC)
mV min. 100 k Ώ load impedance
thermocouple 20 Ώ
Inputs
programmable functional inputs
for external emissivity adjustment,
ambient temperature compensation,
trigger (reset of hold functions)
Cable length
3m
Current draw
max. 100 mA
Power Supply
8-36 V DC
Tobject > Tsensing head + 25°C
Ɛ = 1, Response time 1 s
3)
with dynamic adaptation at low signal levels
1)
2)
Innovative Infrared Technology
"