Humidity and Temperature Sensor type PC-ME0 pages
Galltec Mess- und Regeltechnik GmbHt
D-71145 Bondorf . Germany t
Tel. +49 (0)7457-9453-0 . Fax +49 (0)7457-3758 t
E-Mail: sensoren@galltec.de . Internet:www.galltec-mela.det
MELA Sensortechnik GmbH
D-07987 Mohlsdorf-Teichwolframsdorf . Germany
Tel. +49(0)3661-62704-0 . Fax +49(0)3661-62704-20
E-mail:mela@melasensor.de . Internet: www.galltec-mela.de
Product info sheet no. C 2.4
Humidity/-temperature sensor
Meteorological design
Description
Mela®-humidity/-temperature sensors in the PC-ME series with
a fixed connecting cable (5 m), PK-ME series without cable or RCME series with a robust aluminium connecting head and terminal
screws are compact sensors in a rod-type design. They have a
high degree of accuracy and have been specially developed for
meteorological applications. All the sensors in the series are fitted
with the ZE20-type membrane filter.
We recommend that you use the version with the the ZE 21/ZE22
¹) type sintered high-grade steel filter (filter programme see product
info sheet no. F 5.1)at high wind speeds or if the sensor is exposed
to salt mist, sand or dust (near the sea, industrial estates etc.).
The advantage of the .../9 series is the improved temperature
dynamics, in particular at low air speeds.
t
1) In the series …./9 it is not possible to exchange the protective plastic t
t basket ZE16 with other filters.
Technical Data
Output 1: relative humidity
measuring range 1 ...................................................... 0...100% rh
output signal 1 ..................................... 0...1V, 0...10V or 4...20mA
accuracy (5...95%rh at 10...40°C) .................................... ±2% rh
influence of temperature <10°C, >40°C ......... <0.1%/K additional
Output 2: temperature
measuring range 2 ..................................................... -30...+70° C
output signal 2 ..................................... 0...1V, 0...10V or 4...20mA
accuracy
tt
0...1V (-27...70°C) .............................................. ±0.2 K
t 0...10V (-29...70°C) ............................................ ±0.2 K
tt
4...20mA (RC) ..................................................... ±0.3 K
influence of temperature <10°C, >40°C ...... ±0.007 K/K additional
measuring element (ref. DIN EN 60751) ..... Pt 100 1/3 DIN class B
Other data
ambient temperature ................................................... -40...+80°C
degree of protection sensor/electronic ........................ IP 30/IP 65
operating voltage
t
voltage output 0...10V ............................... 15...30 V DC
t
voltage output 0...1V ................................... 6...30 V DC
t
current output ............................................ 12...30 V DC
load resistance (0...10V, 0...1V) .............................. ≥10 kΩ/≥2 kΩ
load (current output) .............................................. acc. diagramm
power consumption
t
0...10 V, 2 x 0...1V ................................................ <5mA
t
0...1V .................................................................... <1mA
minimum air speed always at right angles to the sensor
output:t 0...10V, 2x 0...1V ............................................. ≥0.5 m/s
t
4...20mA, 2x 0...10V ........................................... ≥1 m/s
t
2x 4...20 mA ..................................................... ≥1.5 m/s
self-heating coefficient Pt100 (v=2 m/s in air) ............... 0.2 K/mW
Directive about electromagnetic compatibility
2004/108/EG
t
DIN EN 61326-1 .......................................... issue 10/06
t
DIN EN 61326-2-3 ....................................... issue 05/07
Special versions available on request
Type Versions
Measured
variable
Output
signals
F
rel. humidity
0...10 V
0...1 V
C
0...10 V, Pt100
r.h. + temp. 0...1 V, Pt100
K
2 x 0...10 V
r.h. + temp.
2 x 0...1 V
Pt100
T
0...10 V
temperature
0...1 V
weight
Sensor with 5 m cablet
Sensor without cablet
Measured
variable
Output
signals
4...20 mA
0...10 V
0...1 V
4...20mA, Pt100
C
0...10 V, Pt100
r.h. + temp.
0...1 V, Pt100
2 x 4...20 mA
K
2 x 0...10 V
r.h. + temp.
2 x 0...1 V
Pt 100
4...20 mA
T
temperature
0...10 V
0...1 V
weight
F
rel. humidity
/x
with filter
with integrated
ZE20 or ZE21
PTFE filter
Pt-100-platinum protection ZE16
chip
Pt-100 glas
FP* 2/x - ME
FP* 1/x - ME
CP* 2/x - ME
CP* 1/x - ME
KP* 2/x - ME
KP* 1/x - ME
TP* 5/x - ME
TP* 2/x - ME
TP* 1/x - ME
approx. 310 g
FP* 2/9 - ME
FP* 1/9 - ME
CP* 2/9 - ME
CP* 1/9 - ME
KP* 2/9 - ME
KP* 1/9 - ME
TP* 5/9 - ME
TP* 2/9 - ME
TP* 1/9 - ME
approx. 300 g
*=C
*=K
with filter
with integrated
ZE20 or ZE21
PTFE filter
Pt-100
protection ZE16
platinum chip
Pt-100 glas
FRC 3/x - ME
FRC 2/x - ME
FRC 1/x - ME
CRC 3/x - ME
CRC 2/x - ME
CRC 1/x - ME
KRC 3/x- ME
KRC 2/x - ME
KRC 1/x - ME
TRC 5/x - ME
TRC 3/x - ME
TRC 2/x - ME
TRC 1/x - ME
approx. 310 g
FRC 3/9 - ME
FRC 2/9 - ME
FRC 1/9 - ME
CRC 3/9 - ME
CRC 2/9 - ME
CRC 1/9 - ME
KRC 3/9 - ME
KRC 2/9 - ME
KRC 1/9 - ME
TRC 5/9 - ME
TRC 3/9 - ME
TRC 2/9 - ME
TRC 1/9 - ME
approx. 300 g
please select the appropriate filter (refer also to data sheet F5.1)
series P*, RCttt
membrane filter ZE20
t
→ x=5t
t
sintered high-grade steel filter ZE21t
→ x=6
This information is based on current knowledge and is intended to provide details of our products and their possible applications. It does not, therefore, act as a guarantee of specific
properties of the products described or of their suitability for a particular application. It is our experience that the equipment may be used across a broad spectrum of applications under
the most varied conditions and loads. We cannot appraise every individual case. Purchasers and/or users are responsible for checking the equipment for suitability for any particular
application. Any existing industrial rights of protection must be observed. The perfect quality of our products is guaranteed under our General Conditions of Sale. Issue: January 2014
C24_E. Subject to modifications.