GC / KC / ZC.D / ZC.HD0 pages
Galltec Mess- und Regeltechnik GmbHt
MELA Sensortechnik GmbH
D-71145 Bondorf . Germany t
Tel. +49 (0)7457-9453-0 . Fax +49 (0)7457-3758 t
E-Mail: sensoren@galltec.de . Internet:www.galltec-mela.det
D-07987 Mohlsdorf-Teichwolframsdorf . Germany
Tel. +49(0)3661-62704-0 . Fax +49(0)3661-62704-20
E-mail:mela@melasensor.de . Internet: www.galltec-mela.de
Product info sheet no. C 4.7
Humidity/-temperature sensors
for industrial applications up to 200°C, up to 25 bar
Description
MELA®-humidity/-temperature sensors in this series are supplied
with a robust aluminium die cast housing with an inox or aluminium
sensor part to measure relative humidity or relative humidity and
temperature in air and other non-aggressive gases for a working
temperature range of up to 200°C.
The pressure-proof executions „D“ and „HD“ can be used at pressures up to 25 bar, at temperatures up to 125°C or up to 160°C.
These sensors are ideally suited for industrial applications, e.g. in
drying processes.
The advantages of the series .../9 are its improved dynamics, in
particular at low air speeds and also its increased service life, even
under more challenging operating conditions (pollutant impact or
permanent humidity > 95 %rh).
When air speeds are extremely high combined with a high number
of particles, using the series .../9 is not recommended.
ZC.D
ZC.HD
GC
KC
Type versions
Measured
variable
Analogue
output
0...20 mA
F
4...20 mA
rel. humidity
0...10 V
0...20 mA, Pt100
C
4...20 mA, Pt100
r.h. + temp. 0...10 V, Pt100
2 x 4...20 mA
K
2 x 0...10 V
r.h. + temp.
Pt 100
T
4...20 mA
temperature
0...10 V
weight approx.
Technical data
(Order designation)
GC series
KC series
wall version duct version
FGC 4/x
FGC 3/x
FGC 2/x
CGC 4/x
CGC 3/x
CGC 2/x
KGC 3/x
KGC 2/x
TGC 5/5
TGC 3/5
TGC 2/5
380 g
ZC series
two-piece
FKC 4/x
FKC 3/x
FKC 2/x
CKC 4/x
CKC 3/x
CKC 2/x
KKC 3/x
KKC 2/x
TKC 5/5
TKC 3/5
TKC 2/5
470 g
FZC 4/x
FZC 3/x
FZC 2/x
CZC 4/x
CZC 3/x
CZC 2/x
KZC 3/x
KZC 2/x
TZC 5/5
TZC 3/5
TZC 2/5
500 g
/x please select the appropriate filter (refer also to datasheet F5.1)
series tGC: t
open protective basket ZE16t
t
integr. element filter made of PTFE and ZE16t
series KC,ZC: t sintered inox filter ZE13t
t
integr. element filter made PTFE and ZE04t
Measured
variable
Analogue
output
0...20 mA
4...20 mA
0...10 V
0...20 mA, Pt100
C
4...20 mA, Pt100
r.h. + temp. 0...10 V, Pt100
K
2 x 4...20 mA
r.h. + temp.
2 x 0...10 V
weight approx.
F
rel. humidity
/x
→
→
→
→
x=5
x=9
x=5
x=9
ZC.D series ZC.H series ZC.HD series
25 bar
200°C
25 bar, 160°C
FZC 4.D/x
FZC 3.D/x
FZC 2.D/x
CZC 4.D/x
CZC 3.D/x
CZC 2.D/x
KZC 3.D/x
KZC 2.D/x
520 g
FZC 4.H/x
FZC 3.H/x
FZC 2.H/x
CZC 4.H/x
CZC 3.H/x
CZC 2.H/x
KZC 3.H/x
KZC 2.H/x
520 g
FZC 4.HD/x
FZC 3.HD/x
FZC 2.HD/x
CZC 4.HD/x
CZC 3.HD/x
CZC 2.HD/x
KZC 3.HD/x
KZC 2.HD/x
520 g
please select the appropriate filter (refer also to datasheet F5.1)
seriest ZC.H, ZC.D, ZC.HDttt
tt
sintered inox filter ZE13
t
→ x=6
tt integr. element filter made PTFE and ZE04t → x=9
Humidity
measuring range .......................................................... 0...100%rh
accuracy (10...40°C; 5...95%rh) ...................................... ±2.0%rh
influence of temperature <10°C, >40°C .......................... <0.1%/K
Temperature
measuring element (ref. DIN EN 60751) ................ Pt 100 class B
measuring range
tttt series GC............................................ -20...+80°C
tttt series ZC, ZC.D, KC .......................... -25..+125°C
tttt series ZCx.H, ZCx.HD ......................... 0...+200°C
accuracyttt output: 0...10 V ........................................... ±0.2 K
tttt output: 4...20 mA ........................................ ±0.3 K
influence of temperature <10°C, >40°C....................... ±0.007 K/K
Other data
ambient temperature
transmitter part ............................................................ -40...+80°C
sensor parttt series GC ........................................... -40...+80°C
tttt series ZC, KC, ZC.D ......................... -40...+125°C
tttt series ZC.HD ....................................-40... +160°C
tttt series ZC.H ..................................... -60... +200°C
operating voltage
t
current output ........................................ 2-wire...12...30V DC
t
voltage output ................................ 3/4-wire... 24V±10% ACt
t
or .......................................................................15...30 V DC
degree of protection
ttt
transmitter part ............................................ IP 65
ttt
sensor head .../6 (xKC, xZC) ....................... IP 65
tt
sensor head .../9 (xKC, xZC) ....................... IP 00
tt
sensor head (xGC) ...................................... IP 30
housing material
t
sensor part (except series GC) ....................................... inox
t
sensor part series GC ........................................... aluminium
t
transmitter part ............................ pressure die casting of alu
load:
Ω= operating voltage - 10 V DC ± 50Ω
(current output)t
0.02 A
load resistance (voltage ouput) .......................................... ≥10kΩ
power consumption (voltage output) ................................... <5mA
self-heating coefficient Pt100 (v=2 m/s in air) ......... 0.2 K/mW
Directive about electromagnetic compatibility .................. 2004/108/EG
t
t
DIN EN 61326-1 .................................................... issue 07/13
DIN EN 61326-2-3 ................................................... issue 07/13
Special versions available on request
This information is based on current knowledge and is intended to provide details of our products and their possible applications. It does not, therefore, act as a guarantee of specific
properties of the products described or of their suitability for a particular application. It is our experience that the equipment may be used across a broad spectrum of applications under
the most varied conditions and loads. We cannot appraise every individual case. Purchasers and/or users are responsible for checking the equipment for suitability for any particular
application. Any existing industrial rights of protection must be observed. The perfect quality of our products is guaranteed under our General Conditions of Sale.
Iss