Brooks® Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters0 pages
1
Models MT 3809 & 3819
Data Sheet
DS-VA-MT3809-3819-eng
September, 2008
Brooks® Models MT 3809 and 3819
Metal Tube Variable Area Flowmeters
with Optional Transmitters and Alarms
Model MT 3809
• Broad range of flow capacities
• 2% Full scale accuracy
• Versatile construction for all gas, liquid, steam
applications
• Operable under high temperatures and pressures
• Flanged or female NPT connections
• Optional 4-20mA and HART® programmable
microprocessor transmitter with or without alarms
and pulse output for totalization
• Electronics designed with either intrinsically safe
or explosion proof construction to meet UL (US &
Canada) ATEX certifications and CE requirements
DESCRIPTION
The Brooks® Models MT 3809 and MT 3819 Variable
Area Flowmeters are rugged, all metal flowmeters
offering 2% full scale accuracy. The Model MT 3809 is
constructed with stainless steel components for
measuring a variety of gas, liquid and steam
applications while the Model MT 3819 utilizes a
ETFE (Tefzel™) lining for aggressive liquid and gas
applications.
Flow rate indication is provided by means of magnetic
coupling where a magnet, encapsulated in the float, is
coupled to a rotatable magnet located in the rear of the
indicator, thus turning the dial indicator mounted on
the meter.
Optional accessories available include 4-20 mA output
with HART microprocessor transmitter with or without
configurable alarms and pulse output for totalization.
Also available are front adjustable inductive alarms,
high temperature or stainless steel indicator housings,
valves, flow controllers and material certifications.
SPECIFICATIONS - METER
Capacities, Pressure Drop and Viscosity Immunity
Ceiling
Refer to Tables 1A and 1B
Accuracy
Standard Flow Accuracy: ± 2% Full Scale
Optional Flow Accuracy: ± 1% Full Scale
Repeatability
0.25% Full Scale
Pressure Ratings
Refer to Table 2 for Model MT 3809 maximum
non-shock pressure. Model MT 3819 pressure rating
is dependant on flange rating.
Pressure Equipment Directive (PED) 97/23/EC
Flow meter complies under Sound Engineering
Practices (SEP) or Categories I, II or III