O-ring Seal Flowmeter Model 13050 pages
1
O-ring Seal Flowmeter
Model 1305
Data Sheet
DS-VA-1305-eng
March, 2008
Scales
Length: Size 8 and 10— 75 mm (3”)
Size 12 — 127 mm (5”)
Graduations:
Standard: On-tube printed scale (Millimeter scale with
approximate calibration curve, direct reading gpm
water or scfm air) OR Detachable printed scale
(Choice of direct reading units, millimeter or
percentage of maximum flow with factor tag.)
Ambient Temperature Limits
33°F to 125°F (1°C to 52°C)
Operating Fluid Temperature Limits
Maximum: 250°F (121°C) for gas service
Minimum: 33°F (1°C)
Connections
Standard: Female NPT
Connection Orientation
Standard: Vertical inlets and outlets
With Alarm: Horizontal outlets
Meter Dimensions
Refer to Figure 1
• Capacity ranges 0.8 to 50 gpm; 3 to 50 scfm
• O-ring seal construction
• Sturdy bolted side-plate construction
• Standard NPT connections
• Vertical inlets and outlets standard,
horizontal outlet with alarm
• Alarm switch adjustable for high or low flow
indication
DESCRIPTION
The Brooks® Model 1305 glass tube flowmeters provide
a low cost means of flow rate indication and alarm
signaling. They are designed for applications where the
metering accuracy requirements are not severe. These
meters are ideal for purge type service, seal oil systems,
bearing lubrication and cooling water indication. Model
1305 is available with vertical inlets and outlets and
standard materials of construction only. A general purpose
alarm, with flow contacts over the entire flow range, is
optional.
SPECIFICATIONS
Capacities and Pressure Drops
Refer to Table 1
Accuracy
Standard Flow Accuracy: ±10% Full Scale from 100% to
10% of scale reading
Optional Flow Accuracy: ±5% Full Scale from 100% to
10% of scale reading
Repeatability
1% Full Scale
Pressure Ratings
Meter Maximum Working Pressure (psig)
at 250°F (121°C) for gases
8 200
10 150
12 75
Note: Hydrostatic test pressure is 1.5 times the working pressure
Model 1305