CoolPoint vortex flow meter for water or corrosives CoolPoint D2 Totalizer series (3/4 -2 inch)0 pages
U
N
I
V
E
R
S
A
L
Max ows range from
Max pressure
Temperature range
®
F L O W
6-200 GPM (23-750 LPM)
300 PSI (20 Bar)
32-210°F (2-99°C)
CPD2 series
3/4-2 inch Flow Totalizer
M O N I T O R S
UNIVERSAL
Flow Monitors
®
™
CoolPoint
Vortex Shedding
Totalizing
Flowmeter
CoolPoint™ shown
with D2 totalizer
Description
User-Congurable Options
This owmeter is made for water, water/glycol coolant
or low viscosity uids. Display is a 6-digit LED. Shows
ow rate or toggle between running and resettable
totals. Push button selection for LPM or GPM. It has
the following features:
• Pulse output
• LED digital display (total or rate)
• No moving parts to clog or wear
• Certied CSA and CE
Features selectable:
• Engineering units (Gallons, Liters)
• Rate or total display only
Instrument Specications
•
Electrical Specications
•
•
Input Power: 10 - 30 VDC @ 80 mA
Electrical Connection
Pin Connector (standard)
Pigtails (optional)
Junction Box with terminal strip (optional)
Material Specications
Flow bodies of brass or 316 Stainless Steel with
PVDF sensors and Viton® seals standard. PEEK sensors used for high temperature option.
•
•
•
•
•
Flow
Visual readout: 6 digit LED, 0.3" digit height
Accuracy: ±1.5% of indicated total
Turndown (ratio of max to minimum ow rates):
10:1 at all temperatures and 20:1 available
optionally for standard temperatures.
Pressure
300 PSIG (20 Bar) operating pressure
General
Fluid temperature limits: 35-150° F (2-66° C) standard, 210° F (99° C) with E22 high temp option.
Enclosure rating: IP 65, Type 1, 3, 4, 12 and 13
Pipe Connections:
Female NPT, BSPP & BSPT
Back pressure of 10 PSIG required.
(See manual for elevated temperature.)
Response time 450 ms