CoolPoint vortex flow meter for water or corrosives Coolpoint Flow/Temperature Series0 pages
U
N
I
V
E
R
S
A
L
Maximum ow ranges from
Max pressure
Temperature range
®
F L O W
M O N I T O R S
CT 3/4-2 inch Flow
and Temperature
Transmitter
25-200 GPM (95-750 LPM)
300 PSI (20 Bar)
32-210°F (2-99°C)
™
CoolPoint
UNIVERSAL
Flow Monitors
®
Vortex Shedding
Flowmeter and
Temperature Transmitter
Flow/Temp
CoolPoint™ with
Rotatable Enclosure
option
Description
User-Congurable Options
This owmeter/temperature transmitter is made for
water, water/glycol coolant or low viscosity uids.
It has the following features:
• Flow rate transmitter 4-20 mA
• Temperature transmitter 4-20 mA
• Solid state relay can be congured as alarm or
pulse out
• LED digital display
• No moving parts to clog or wear
• Certied CSA and CE
Features that are selectable on 4-20 mA units include:
• Selectable alarm state (N.O. or N.C.)
• Set point or pulse output
• Engineering units (GPM, LPM)
• Fahrenheit or Celsius
Instrument Specications
•
Electrical Specications
•
•
•
•
Input Power: 10 - 30 VDC @ 80 mA
Output: 4-20mA for ow with solid state relay
congurable for set point or pulse out
Output: 4-20mA for temperature
Electrical Connection
Pin Connector (standard)
Pigtails (optional)
Junction Box with terminal strip (optional)
•
Material Specications
•
Flow bodies of brass or 316 Stainless Steel with
PVDF sensors and Viton® seals standard. PEEK
sensors used for high temp for uids above 150° F.
•
•
•
Flow
Visual readout: 3 digit LED, 0.3" digit height
Response time: 450 ms.
Deadband for alarm: 5% of full scale (maximum ow)
Accuracy: ±2% full scale
Repeatability: ±.25% of indicated
Turndown (ratio of max to minimum ow rates):10:1
at all temperatures and 20:1 available optionally for
standard temperatures.
Temperature
Response time: 1 1/2 seconds to 66% of change
Deadband for alarm: ±2% full scale
Accuracy: ±3% of indicated temperature
Repeatability: ± .25% of indicated
Output: 4 mA @32°F, 20mA @210°F linear
Pressure
300 PSIG (20 Bar) operating pressure
General
Fluid temperature limits: 35-150° F (2-66° C)
standard, 150-210° F (66-99° C) optional.
Enclosure rating: IP 65, Type 1, 3, 4, 12 and 13
Pipe Connections:
Female NPT, BSPP & BSPT
Back pressure of 10 PSIG usually required.
(See manual for elevated temperature.)
Viton® is a registered trademark for DuPont Performance Elastomers.