CPM0 pages
U
N
I
V
E
R
S
A
L
Max ow
Max pressure
®
Temperature range
F L O W
50 GPM (190 LPM)
200 PSI (13.6 bar) Polysulfone,
300 PSI (20 Bar) Brass
35-150°F (2-66°C)
CPM 1 inch
Rate or Total
™
M O N I T O R S
UNIVERSAL
Flow Monitors
CoolPoint
®
Flowmeter for
Continuous or Batch
Water Add on
Concrete Trucks
Polysulfone CPM
Description
User-Congurable Options
This owmeter is for monitoring water add on
concrete trucks. It operates in batch (total) mode or
rate for continuous mix.
• No moving parts to hang up
• 11/2% accuracy
• Not destroyed by compressed air
• 3 digit display optional
•
Electrical Specications
•
•
•
•
Input Power: 10 - 30 VDC @ 80 mA
Electrical Connection
Pin Connector (standard)
Weather pack
Instrument Specications
•
•
Material Specications
Flow bodies of brass or Polysulfone with PVDF
sensors and Viton® seals standard.
Engineering units (GPM, LPM)
•
•
•
•
Max ow 50 GPM
Flow
Accuracy: ±11/2% of indicated total
11/2% Full Scale for rate
Turndown: 10:1
Operating Pressure
200 PSI (13.6 bar) Polysulphone,
300 PSIG (20 Bar) Brass
General
Response time: 450 ms
Fluid temperature limits: 35-150°F (2-66°C)
continuous use.
Enclosure rating: IP 65, Type 1, 3, 4, 12 and 13
Pipe Connections:
1 inch NPT female
Pulse or 4-20 mA rate output
Mounting lugs integral to body
Back pressure of 10 PSIG required
Viton® is a registered trademark for DuPont Performance Elastomers.