Modular controller type 5TCOM0 pages
TEMPERATURE CONTROLLER FOR HOT RUNNER MOULDING SYSTEMS
Hot Runner Controls
Mould Temperature Control
Sequential Moulding
Production Monitoring
Parc Industriel Sud - Groissiat
F - 01100 OYONNAX
Tel (33) 04.74.77.34.53
Fax (33) 04.74.73.90.18
e-mail sise@sise.fr
web: www.sise.fr
SELF-TUNING
CONTROL MODULE
WITH EUROMAP 17
COMMUNICATION
Ref: 5 TCOM
5TCOM_uk.indd
: 220/240 V 50/60 Hz single phase
: 0 to 230 V x 20 A (4600 W) Phase control or pulse triggered & zero crossing
(Low voltage with addition of transformer)
: Thermocouple Fe/Co (J) linearisation, accuracy 0,5%
0 to 500°C (or 32 to 932°F according to configuration)
or Thermocouple K with linearisation, accuracy 0,5%
0 to 500°C (or 32 to 932°F according to configuration)
: SELF-TUNING or programmable P.I.
: COMMUNICATION via RS485 using EUROMAP 17 protocole
Automatic and manual
2nd Setpoint
Programmable softstart (either 15% / 100°C or rate °C/minute)
Display of current intensity (A)
: Open thermocouple (displays and stops heating)
Inverted thermocouple (displays and stops heating)
Upper / Lower deviation alarm (programmable)
Centralised alarm (output from cabinet relays and via EUROMAP 17 link)
TRIAC failure
Load failure
Fuse GRB 20A (on cabinet)
Protection against supply overvoltage and module overheating
: Allows transmission between moulding machine or PC and
controllers, via RS485, according to EUROMAP 17 standard, of :
- setpoints and process parameters etc... to controllers
- actual temperature, alarms etc... to moulding machine or PC
SUPPLY
OUTPUT
INPUT
CONTROL
FUNCTIONS
SAFETY
FEATURES
EUROMAP 17