P550W Series (Up to 350 SCFD continuous)0 pages
P550W Series
(Up to 350 SCFD continuous)
•
Air delivery up to 550 SCFD
•
Available in 120 VAC & 220 VAC models
•
Remote real-time data and alarm reset capabilities
•
SNMP communication compatible
• Digital display of all operating parameters
• 8,000 hour maintenance interval
•
Compact and lightweight
•
Versatile installation
•
Ultra quiet compressor
Accessories:
• Universal Rack Mounting Kit (P011674)
• Wall Mounting Kit (P011773)
• 6-Month Maintenance Kit (P011798)
• 8,000 Hour Maintenance Kit (P011673)
• Cycle Module Interface (P012341)
• 3/8” Tubing (PMP26A20 - sold per foot)
120 VAC
P550W
Low Pressure
P552W
P550WLP
Standard Pressure
220 VAC
P552WLP
w/ 4-Port Outlet
(above model #) + H
w/ Outdoor Enclosure
(above model #) + X
Specications
P550W
P550WLP
Output Capacity
Power Requirements
110 - 125 VAC, 50/60 Hz
(15 Amp service recommended)
208 - 253 VAC, 50/60 Hz
(15 Amp service recommended)
7.0 Amps
3.5 Amps
2 - 15 PSIG
(13.8 - 103.4 KPa)
0.30 - 7.50 PSIG
(2.07 - 51.71 KPa)
Outlet Air Relative Humidity
Heatless Desiccant
Operating Temperature Range
40° to 85° F (5° to 30° C) (optimal)
Noise Level
Dimensions
48 dBA at 10' (3 m)
Standard Alarms - complete readings of all critical measurement points, individual alarm
indication display, including SNMP communication
3/8” tube tting
(w/ 4-Port Outlet - 3/8” Press-to-lock tube ttings and shut off valves)
12" D x 17.25" W x 27" H (30.5 cm D x 43.8 cm W x 68.6 cm H)
Weight
Page 3
0.30 - 7.50 PSIG
(2.07 - 51.71 KPa)
Two-cylinder, 1/3 HP, oil-less type
Dehydrating Method
Outlet Connections
2 - 15 PSIG
(13.8 - 103.4 KPa)
Less than 2% RH
Compressor Type
Alarms
P552WLP
Normal: Up to 350 SCFD (9.9 SCMD) continuous
Maximum: 550 SCFD (15.6 SCMD) emergency
Running Amps
Outlet Pressure Range
P552W
74 lbs (33.6 kgs)
PUREGAS, LLC
800-521-5351
www.puregas.com
R0413
"