P1500W Series (250 - 1,200 SCFD)0 pages
P1500W Series
(250 - 1,200 SCFD)
•
Air delivery up to 1500 SCFD
•
Available in 120 VAC & 220 VAC models
•
Remote real-time data and alarm reset capabilities
•
SNMP communication compatible
• Digital display of all operating parameters
• 8,000 hour maintenance interval
•
Compact and lightweight
•
Versatile installation
•
Ultra quiet compressor
Accessories:
• Universal Rack Mounting Kit (P011674)
• Wall Mounting Kit (P011773)
• 4-Port Outlet Manifold Kit (P012099)
• 6-Month Maintenance Kit (P011910)
• 8,000 Hour Maintenance Kit (P012252)
•
•
Cycle Module Interface (P012341)
3/8” Tubing (PMP26A20 - sold per foot)
120 VAC
P1500W
Low Pressure
P1502W
P1500WLP
Standard Pressure
220 VAC
P1502WLP
Specications
P1500W
P1500WLP
Output Capacity
Power Requirements
110 - 125 VAC, 50/60 Hz
(15 Amp service recommended)
208 - 253 VAC, 50/60 Hz
(15 Amp service recommended)
7.0 Amps
3.5 Amps
2 - 15 PSIG
(13.8 - 103.4 KPa)
0.30 - 7.50 PSIG
(2.07 - 51.71 KPa)
Outlet Air Relative Humidity
Compressor Type
Two-cylinder, 3/4 HP, oil-less type
Two-cylinder, 1/2 HP, oil-less type
40° to 85° F (5° to 30° C) (optimal)
Noise Level
48 dBA at 10' (3 m)
Standard Alarms - complete readings of all critical measurement points, individual alarm
indication display, including SNMP communication
Outlet Connections
3/8" tube tting
12" D x 17.25" W x 27" H (30.5 cm D x 43.8 cm W x 68.6 cm H)
Weight
R0413
0.30 - 7.50 PSIG
(2.07 - 51.71 KPa)
Heatless Desiccant
Operating Temperature Range
Dimensions
2 - 15 PSIG
(13.8 - 103.4 KPa)
Less than 2% RH
Dehydrating Method
Alarms
P1502WLP
Normal: Up to 1,200 SCFD (34 SCMD) continuous
Maximum: 1,500 SCFD (42.5 SCMD) emergency
Running Amps
Outlet Pressure Range
P1502W
80 lbs (36.3 kgs)
PUREGAS, LLC
800-521-5351
www.puregas.com
Page 4
"