KIRAY 2000 pages
KIRAY 200
Infrared thermometer
Infrared thermometer KIRAY 200 is an infrared thermometer used
to diagnose, inspect and check any temperature. Thanks to its
elaborated optical system, it allows an easy and accurate
measurement of little distant targets. KIRAY 200 instrument has
an internal memory which can save up to 20 measurements.
Technical features
Distance from the target
Distance
Diameter
Instrument features
Spectral response.......................8 -14 µm
Optical..........................................D.S : 30:1 (50 mm at 1500 mm)
Response time.............................Less than 1 second
Temperature range......................From -50 to +850°C
Accuracy*....................................From -50 to -20°C : ±5°C
From -20 to +200°C : ±1.5% of reading ±2°C
From +200 to +538 °C : ±2% of reading ±2°C
From +538 to +850°C : ±3.5% of reading ±5°C
Display resolution.......................0.1 C°
Emissivity....................................Adjustable from 0.10 to 1.00
(pre-set at 0.95)
Over range indication.................Display indication : « -0L » for a negative
over range, « 0L » for a positive over range.
Laser sighting.............................Wavelength : 630-670 nm
Output < 1mW, Class 2 (II)
Positive or negative
temperature indication................Automatic (no indication for a positive
temperature)
(-) sign for a negative temperature
Display.........................................4 ½ digits with LCD backlighted display
Auto-extinction............................Automatic after 7 seconds of inactivity
High/low alarm.............................Flashing signal on display and beep signal
with adjustable thresholds
Power supply...............................Alkaline 9V battery
Autonomy....................................38 h (inactive laser and backlight)
15 h (active laser and backlight)
Use temperature..........................From 0 to +10°C for a short period
From 11 to +50 °C for a long period
Storage temperature...................From -20°C to +60°C
Relative humidity........................From 10% to 90%RH in operating mode and
>80%RH in storage
Dimensions..................................175 x 110 x 45 mm
Weight..........................................230 g (included battery)
Memory........................................20 temperature values with unit of measurement
(°C or °F)
●
Supplied with
thermocouple K probe
150
5
300
10
900
30
mm
mm
D:S=30:1
50 mm at 1500 mm
*Accuracy for an ambient temperature from 18 to 28°C (with a relative humidity lower
than 80% RH)
YES
NO
Make sure that the target is larger than the size of the laser sighting.
●
Thermocouple K probe features
Temperature range......................From -40 to +400°C
Display range...............................From -50 to +1370°C
Resolution...................................0.1°C
Accuracy......................................±1.5% of reading ±3°C
Cable length................................1 m