SW822 Paired Double Pole Single Throw for Motor Reversing0 pages
100A
Application
Interrupted
Thermal Current Rating (Ith)
Uninterrupted
100A
Intermittent Current Rating:
30% Duty
185A
40% Duty
160A
50% Duty
140A
60% Duty
130A
70% Duty
120A
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:
(in accordance with UL583*)
SW822
800A at 80V
Maximum Recommended Contact Voltages (Ue):
SW822
SW822 Paired Double Pole Single Throw for Motor Reversing
(Part of the SW80 Series)
The SW822 has been designed for Motor Reversing applications with direct current loads,
particularly motors as used on electric vehicles such as industrial trucks. Developed for both
interrupted and uninterrupted loads, the SW822 is suitable
for switching Resistive, Capacitive and Inductive loads.
•t
Interrupted current - opening and closing on load with
frequent switching (results in increased contact resistance).
•t
Uninterrupted current - no or infrequent load switching
requirements (maintains a lower contact resistance).
The SW822 features single pole double breaking main contacts with
silver alloy tips, which are weld resistant, hard wearing and have
excellent conductivity. The SW822 has M8 stud main terminals and
6.3mm spade coil connections. Mounted using supplied brackets,
mounting can be horizontal or vertical, when vertical the M8 contact
studs should point upwards. If the requirement is for downwards
orientation we can adjust the contactor to compensate for this.
SW822
96V D.C.
Typical Voltage Drop per pole
across New Contacts at 100A
Dimensions in mm [inches]
50mV
Mechanical M.T.B.F
>5 x 106
Coil Voltage Available (Us)
(Rectifier board required for A.C.)
From 6 to 240V D.C.
Coil Power Dissipation:
Highly Intermittent Rated Types
20 - 30 Watts
Intermittently Rated types
15 - 20 Watts
Prolonged Rated Types
13 - 15 Watts
Continuously Rated Types
7 - 13 Watts
Maximum Pull-In Voltage (Coil at 20˚ C) Guideline:
Highly Intermittent Rated types
(Max 25% Duty Cycle)
60% Us
Intermittently Rated types
(Max 70% Duty Cycle)
60% Us
Prolonged Operation
(Max 90% Duty Cycle)
60% Us
Continuously Rated Types
(100% Duty Cycle)
66% Us
Drop-Out Voltage Range
10 - 25% Us
Typical Pull-In Time
(N/O contacts to close)
20ms
Typical Drop-Out Time (N/O Contacts to Open) §:
5ms
50ms
= Interrupted
= Uninterrupted
Note: Where applicable values shown are at 20˚C
* Please check our web site for product UL status
Magnetic Latching† (Not fail safe)
200
Closed Contact Housing‡
Environmentally Protected IP66
(see SW822P Catalogue sheet)
Current (Amperes)
Contact Performance Key:
Interrupted and
Uninterrupted
Current
The SW822 has fast drop out times and relatively slow pull-in
times. Motor direction changes can be undertaken without risk of all
contacts being closed at the same time. Note, some coil
suppression such as diodes substantially increase drop out times
and care must be taken to ensure suitable suppression is used (e.g.
diode and resistor in series).
§
•t
•t
•t
•t
v1a-06-13
Performance data provided should be used as a guide only. Some de-rating or variation
from figures may be necessary according to application.
Thermal current ratings stated are dependant upon the size of conductor being used
For further technical advice email: technical@albrightinternational.com
Albright reserve the right to change data without prior notice
0
80
0
70
0
100
60
0
0
Rated suitable for Application
Cable
Key:
80mm2 [0.124inch2]
Mounting Brackets
50
0
Copper busbar
X
○
●
○
○
300
0
Advised Connection Sizes for Maximum Continuous Current
Magnetic Blowouts - High Powered†
400
40
920 gms
X
Armature Cap
0
SW822
X
Magnetic Blowouts†
500
30
Guideline Contactor Weight:
600
X
Auxiliary Contacts - V3
Figures are for guideline
purposes only
700
0
- 40˚C to + 60˚C
Time (Seconds)
3ms
Operating Ambient Temperature
Suffix
Auxiliary Contacts
800
8 - 20ms
Typical Contact Bounce Period
General
900
20
With Diode and Resistor
(Subject to resistance value)
SW822 Available Options
SW822 Contactor Performance
0
With Diode Suppression
10
Without Suppression
○
EE Type (Steel Shroud)
P
X
Contacts
○
○
Large Tips
Connection Diagram
M
Textured Tips
Silver Plating
L
T
X
Coil
○
○
○
○
AC Rectifier Board (Fitted)
Coil Suppression†
Flying Leads
Manual Override Operation
M4 Stud Terminals
X
M5 Terminal Board
F
○
○
Vacuum Impregnation
Key: Optional
○
Standard
●
Not Available X
†
Connections become polarity sensitive
‡
Open Housing Available
Albright International Ltd, Evingar Trading Estate, Ardglen Road, Whitchurch, Hampshire, RG28 +44 UK
Albright International, 125 Red Lion Road, Surbiton, Surrey KT6 7QS, England,Tel: +44 (0) 20 8390 5357, Fax:7BB,(0) 20 8390 1927
Tel: sales@albrightinternational.com or technical@albrightinternational.com Web 890030, Fax: +44 (0)1256 890043
E-mail: +44 (0)1256 893060, Fax: +44 (0)1256 893562, Dedicated Sales Tel: +44 (0)1256 Site: www.albrightinternational.com
E-mail: sales@albrightinternational.com or technical@albrightinternational.com Web Site: www.albrightinternational.com
Copyright © 2010 Albright International Ltd
Copyright © 2013 Albright International LTD