LR-Cal PULSAR-35Cu0 pages
Portable Temperature Calibrator Type Pulsar
PULSAR-35CU
Dry Block Calibrator, up to +600°C
Dry Block Temperature Calibrator PULSAR-35CU
C for mobile or stationary use
C micro processor operated (PID)
C ramp function, thermostat test
Typical applications:
C calibration and checking of all kind of thermometers
C calibration and checking of thermostats
C computer aided calibration via RS232 interface
Technical Data Type PULSAR-35CU: Order-Code: PULSAR-35CU
Temperature range: ambient temperature up to +600°C
Resolution of the display: 0.01 / 0.1°C (display switchable to °F or K)
Stability of regulated temperature: ±0.05°C at 450°C
Mean heating time: 20°C per minute / Mean cooling time: 25°C per minute
Uniformity (at 450°C): radial ±0,15°C, axial ±0,35°C.
Accuracy of integrated temperature measurement: ±0.3°C
Integrated reference probe: Resistance thermometer Pt 100 (3-wire)
Ventilation: integrated, electronical driven.
RS-232 interface: included
Ramp function: min. 0.1°C per minute
Dry block: diameter 35 mm, depth 190 mm, material: copper
Test wells: 1 hole diam. 35 mm x depth 185 mm
Incl. 1 insert with 4 drillings / holes: diam. 4.5 - 6.5 - 9.5 - 12.5 mm)
Optional: insert with customized drillings or without drillings
Power supply: 230 VAC or 115 VAC
Power consumption: 800 VA
Housing: metal, dimension: 160 x 340 x 330 mm, weight 10.1 kg net (shipping weight: 18.2 kg)
NOTE: the stated accuracy is valid for ambient temperature +10...+40°C and is guaranteed for 1 year.
Additional for type PULSAR-35CU-2I: Order-Code: PULSAR-35CU-2I
Version with data acquisition card and two input devices to measure Pt 100 (3-/4-wire, -100...+700°C, ±0.3°C), Thermocouple type J
(0...1000°C, ±1°C) and Thermocouple types K/N/R/S (0...1300°C, ±1°C).
Scope of standard Supply:
Temperature Calibrator PULSAR, power supply cable, fuses kit, thermostats connection cables, instruction manual, test certificate
(traceable), tweezer for inserts removing, 1 insert with holes diam. 4.5 - 6.5 - 9.5 - 12.5 mm, depth 185 mm.
Optional Accessories:
• Order-Code PULSAR-35CU-INS-KS:
• Order-Code PULSAR-35CU-INS-0:
• Order-Code: TEMPKAL-TASCHE:
• Order-Code: TEMPKAL-KOFFER:
• Order-Code: 599.0.000.0003.0:
Insert with drillings as per customers request
Insert without drillings (to be drilled by customer)
Soft bag
Aluminum case
RS232 cable and PC-Windows-Software AQ2sp
With the software AQ2sp it is possible to remote-control the calibrator with a PC.
Automatic or manual calibration of one or more test specimen, stress tests,
thermostat tests. Printing of calibration certificates.
DRUCK & TEMPERATUR Leitenberger GmbH
Bahnhofstr. 33 C D-72138 Kirchentellinsfurt C Germany
Tel.: +49 - 71 21 - 9 09 20 - 0 C Fax: +49 - 71 21 - 9 09 20 - 99
E-Mail: DT-Export@Leitenberger.de C http://www.druck-temperatur.de
Technische Änderungen vorbehalten. Freibleibend C (Rel. 100121) •All technical modifications reserved. Without engagement