nnnnFILTRATION SOLUTIONS
nnnnSYNTEQ XP M/S
nnnnCOALESCING FILTER ELEMENTS
nnnnCompressed Air & Process Filtration
nnnnCoalescing depth filter elements for removal of water,
nnnnoil aerosols, and solid particles from compressed air
nnnnand gas with a retention rate validated according to
nnnnISO 12500-1.
nnnnDonaldson® Synteq XP " filter elements are designed
nnnnfor high quality filtration of compressed air and gas in
nnnnindustrial and general process applications.
nnnnSynteq XP M/S element performance has been
nnnnvalidated in accordance with ISO 12500-1, which
nnnnassures that your application will receive compressed
nnnnair quality as specified by ISO 8573-1.
nnnnHigh performance Synteq XP media provides multiple
nnnninnovations in one product:
nnnn• Engineered blend of fibers with proprietary,
nnnnresin-free bonding system
nnnnSturdy bi-component polyester fibers and
nnnnmicro-fine glass fibers bonded thermally
nnnn• Polyester fibers create a robust structure,
nnnneffectively supporting the high retention rate of
nnnnthe glass fibers
nnnnSynteq XP combines the highest filtration
nnnnperformance with high stability, exceptional dirt-
nnnnholding capacity and very good flow rates at low
nnnndifferential pressures.
nnnnAPPLICATIONS
nnnnSynteq XP coalescing filter elements are
nnnndesigned and developed for the following
nnnnindustries and applications:
nnnnBeverage
nnnnFood
nnnnFinal filtration for control and process air
nnnnPrefilterto protect adsorption dryers (M)
nnnnDust filter downstream applications (M)
nnnnSynteq XP
nnnnDepth Filter Element
nnnnScanning electron
nnnnmicroscope image
nnnnof Synteq XP filter
nnnnmedia cross section
nnnnOperating Pressure psi | Conversion Factor fp |
15 | 0.25 |
30 | 0.38 |
45 | 0.52 |
60 | 0.65 |
75 | 0.78 |
90 | 0.91 |
100 | 1.00 |
115 | 1.13 |
130 | 1.26 |
150 | 1.44 |
160 | 1.52 |
175 | 1.65 |
190 | 1.78 |
200 | 1.90 |
220 | 2.00 |
232 | 2.15 |
Element Type | Flow Rate 100 psi (cfm)* |
2030 | 850 |
3030 | 1130 |
3050 | 1695 |
Sizing example for pressure which
nnnndeviates from nominal pressure:
nnnnVnom = 1350 cfm, operating
nnnnpressure = 130 psi
nnnnVcorr = Vnom/fp
nnnnVcorr = 1350 cfm/1.26 = 1071 cfm
nnnnCalculated Size: Type 3030
nnnn* cfm related to 15 psi abs. and 68°F
"