Shear Beam load cell type H8Q0 pages
SHEAR BEAM
LOAD CELL
TYPE H8Q
APPLICATIONS:
Shear Beam load cell type H8Q can be used in small
capacity weighing systems.
Some applications are:
- Hopper scale
- Floor scale and other electronic scale
MAIN FEATURES:
-
Nickel plateted Alloy Steel construction
Low profile
High accuracy
OIML Certificates n.: TC8382 Revision 0
C of C Number: R60/2000-NL1-13.21 Revision 1
IP67
NOMINAL LOAD: C3: 200-500-1000-2000 Kg
SPECIFICATIONS:
Accuracy Class
Output Sensitivity (=FS)
Max. Capacity
Max. Number of Load Cell Intervals
Ratio of min. LC Verification Interval
Combined Error
Min. Dead Load
Safe Overload
Ultimate Overload
Zero Balance
Excitation, recommended Voltage
Excitation Max.
Terminal Resistance, Input
Terminal Resistance, Output
Insulation Impedance
Temp. Range, Compensated
Temp. Range, Operatine
Storage Temp.
Element Material
Recommended Torque on Fixation
Ingress Protection
OIML R60 C3
mV/V
Kg
C3
2.0 ± 0.002
200-500-1000
2000
3000
15000
%FS
Of Emax
Of Emax
Of Emax
Of FS
V
V
Ω
Ω
MΩ
°
C
°
C
°
C
Nm
10000
≤ ±0.023
0%
150%
300%
≤ ±1.0%
5 ~ 12
18
1000 ± 10
1000 ± 10
≥ 5000 (at 50VDC)
-10 ~ +40
-35 ~ +70
-40 ~ +80
Nickel Plated Alloy Steel
M12:75
IP67
CELMI s.r.l.
Largo Brugnatelli 13/16 20090 BUCCINASCO (MI) ITALY
Tel: +39-0245712209 / 0257503712 Fax: +39-0245705836 / 0257506211
Internet: www.celmi.com mail: info@celmi.com