SUP10 pages
OFF CENTER
LOAD CELL
TYPE SUP1
APPLICATIONS:
Off center load cell type SUP1 can be used in small
capacity weighing systems.
Some applications are:
- Small weighing platforms
- Hopper weighing, etc.
MAIN FEATURES:
-
Universal use
Low cost
Aluminium construction
Independent from center of load application
Platform size 250X300 mm
NOMINAL LOAD: kg 3-5-6-7-8-10-15-20-35-50
S P E C IF IC A T IO N A C C O R D IN G T O V D I/V D E 2637
M E T R O L O G IC A L C H A R A C T E R IS T IC S
N O M IN A L LO A D
IN IT IA L LO A D
M A X IM U M LO A D
N O N -LIN E A R IT Y
H IS T E R E S IS E R R O R
R E P E A T A B ILIT Y E R R O R
C R E E P -30 M IN U T E S
N O M IN A L T E M P E R A T U R E R A N G E
Z E R O T E M P E R A T U R E D R IF T (O V E R 10 °C )
O U T P U T T E M P E R A T U R E D R IF T (O V E R 10 °C )
T H E R M A L G R A D IE N T
E L E C T R IC A L D A T A
N O M IN A L O U T P U T
N O M IN A L O U T P U T T O LE R A N C E
N O M IN A L S U P P L Y V O LT A G E
M A X IM U M S U P P LY V O L T A G E
IN P U T R E S IS T A N C E
O U T P U T R E S IS T A N C E
IN S U LA T IO N R E S IS T A N C E @ 20V
Z E R O O U T P U T T O LE R A N C E
M E C H A N IC A L D A T A
B R E A K IN G LO A D
M A X IM U N S ID E LO A D
D E F L E C T IO N
C A B L E LE N G T H
E N V IR O N M E N T A L C O N D IT IO N S
W O R K IN G T E M P E R A T U R E R A N G E
STO RAG E TEM PERATURE RANG E
H O U S IN G P R O T E C T IO N
P a r.
Ln
Lp
Ll
F lin
Fu
Fv
F cr
B tn
TK0
TKC
Un.
Kg
% Ln
% Ln
% Ln
% Ln
% Ln
% Ln
°C
%Cn
%Cn
°K /h
Cn
Dc
B su
U sm ax
Re
Ra
R is
Do
m V /V
±% C n
V
V
M
±% C n
Ld
Llq
hn
% Ln
% Ln
mm
mm
B tn
B ts
°C
°C
SUBJECT TO CHANGE WITHOUT NOTICE
CELMI s.r.l.
Largo Brugnatelli 13/16 20090 BUCCINASCO (MI) ITALY
Tel: +39-0245712209 / 0257503712 Fax: +39-0245705836 / 0257506211
Internet: www.celmi.com mail: info@celmi.com
3÷50
20
1 50
0,015
0,015
0,0 1
0,017
-1 0+4 0
0,1 7
0,1 7
<5
2
10
1÷10
15
4 10±1 5%
35 0±3%
>2000
2
2 00
1 00
<1
4 50
-2 0+6 0
-2 0+6 0
IP -65