LIQUI-VIEW Base0 pages
The smart and lightweight vortex meter
for monitoring low viscosity, water-like liquids
> Introduction
Mass Flow ONLINE B.V. sells flow measuring and controlling products
through the internet. From the website www.massflow-online.com flow
meters or controllers can be ordered 24 hours a day 7 days a week.
Most products are in stock and will be shipped world-wide within
two working days.
> Description
The new LIQUI-VIEW Base series offer a compact, light weight and
cost-effective solution for monitoring the flow or consumption of
cleansing, cooling or spa water. The unique sensor body and
transmitter design makes LIQUI-VIEW Base one of the most
compact, lightweight vortex meters in the industry.
> LIQUI-VIEW Base series
The LIQUI-VIEW Base series operate on the vortex principle. The
obstruction (bluff body) placed in the flow of the liquid sheds
vortices downstream at a frequency proportional to the velocity of
the liquid. This pattern of vortices is named the Von Kármán vortex
street. A piezo-electric sensor detects the vortices and creates
electrical pulses which are proportional to the liquid flow rate.
The instruments may be mounted in any position.
LIQUI-VIEW Base flow meters can be supplied in ranges from
0,5 l/min up to 150 l/min at max. 12 bar pressure rating.
Furthermore the instruments can be supplied with an
analog output or a pulse output.
> LIQUI-VIEW Base features
ut o moving parts makes it:
N
- Impervious to deposits of hard water
- Maintenance free
ut ow pressure drop
L
ut ounting in any position
M
ut ide flow ranges
W
utFast response
ut uitable for dirty water (circulating, well or filtered waste water)
S
ut ustainable product design
S
- Low power consumption
- Lightweight and compact
> Fields of application
ut ooling water monitor
C
ut eionized water (RO/DI skids)
D
utUltra pure water distribution (medicare, biotech, semiconductor,
t pharmaceutical)
Model
Nominal size
Capacity
Output
Volume / pulse @ 50% FS
Pressure drop (mbar)1)
LVB-06
DN6
0.5 ... 10 l/min
[-A] 4-20mA or [-P] pulse (28 .. 427 Hz)
0.386 ml
(240 * Q2) / 100
LVB-08
DN8
0.9 ... 15 l/min
[-A] 4-20mA or [-P] pulse (30 .. 384 Hz)
0.638 ml
(85.0 * Q2) / 100
LVB-10
DN10
2.0 ... 40 l/min
[-A] 4-20mA or [-P] pulse (26 .. 473 Hz)
1.403 ml
(22.5 * Q2) / 100
LVB-15
DN15
3.5 ... 50 l/min
[-A] 4-20mA or [-P] pulse (20 .. 272 Hz)
3.047 ml
(6.70 * Q2) / 100
LVB-20
DN20
5.0 ... 85 l/min
[-A] 4-20mA or [-P] pulse (14 .. 227 Hz)
6.213 ml
(2.50 * Q2) / 100
LVB-25
DN25
9.0 ... 150 l/min
[-A] 4-20mA or [-P] pulse (12 .. 201 Hz)
12.412 ml
(0.92 * Q2) / 100
Q = flow rate in l/min
t Example for LVB-06-A used at a flow rate of 8 l/min: (240 * 82) / 100 = 153.6 mbar
1) t