Anti-Siphon, Spill-Resistant Vacuum Breakers0 pages
RP/IS-008QT >
nnSpill-Resistant Pressure Vacuum Breaker
nnSizes:
nn3
nn⁄
nn8
nn",
nn1
nn⁄
nn2
nn",
nn3
nn⁄
nn4
nn" and 1" (10, 15, 20, and 25mm)
Function: To protect the potable water supply against back-fl ow from a non-potable source due to negative supply pressure Protection: Against back-siphonage backfl ow >
nnInstallation Requirements
1. Install a minimum of 1" above fl ood level of fi xture if factory deck mounted or not less than 6" if general plumbing
fi eld application. 2. 3. Install bonnet side up and allow for accessibility for testing/service. Do not install in concealed locations or areas where water leakage due to normal wear of the internal parts can cause damage. Do not undersize supply or oversize the valve in relationto demand. Watts 008QT >
3 ⁄ >
3 8 ", >
1 ⁄ >
2 "Patent# 5125429Watts 008QTS ⁄ >
4 ", 1" 4. Do not install where back-pressure can occur. 5. Protect from freezing.Note: Use LӔ suffi x for left-hand outlet. 6. The installation of a strainer ahead of the backfl ow preventer is recommended to prevent fouling of the check assembly and resultant spillage from the valve during repressurizing. >
Installations:
nn008QT Watts P50
Pressure Reducing ValveSolenoid ValveShutoffs Min.of 1"
Recommended Service
Test periodically as required by local jurisdictional authorities.
Replace internal components every fi ve years. >
TestCock
Pressure Temperature
nnStrainer Working Temperature: 33װF 180ְF (0.5C ږ 82C)
Maximum Pressure: 150psi (10.3 bar)
Minimum Pressure: 8psi (55 kPa) >
3 ڢD 4 " Hose Adapterwith strainer washerDispensing InducersSupply Hose Strainer recommended to prevent fouling of
the check assembly and resultant spillage during start up. 6" >
Supply Line
008QT
Flood Rim Level008QT to be installed a minimum of 6" above the fl ood rim if applied for general plumbing
applications. size="-1">