conditionneur RVDT 690 210 266 ATEX0 pages
Aerospace
Energy
Measurement
Railway
Sensorex®
(IS) conditioner for (IS) RVDT sensor
690210266 (IS)
Utilization range
• Electrical :
Power supply: 15VDC to
28VDC
• Storage temperature: -65°C/
+150°C
• Operating temperature: -40°C
/ +85°C
Contact
(IS) 690210266 signal conditioner features 6 wires inductive RVDT sensor signal treatment in
explosive atmosphere. This conditioner delivers a 4 /20mA current output proportional to the
sensor core rod displacement. It has two screw terminals for sensor broken wire detection
or power supply failure.
Meggitt (Sensorex)
Archamps Technopole
196 Rue Louis Rustin
74166 ARCHAMPS- France
Tel: 04 50 95 43 70
Fax: 04 50 95 43 75
www.sensorex.fr
www.meggitt.com
INDUCTEE SENSOR
FILTER ~| 15T02BVDC~
SINUSOIDAL
GENERATOR
DEMODULATOR
U / I DEFAULT ouipur
CONVERTER DETECTION '
Borniers a vis
IScrew terminations!
Meggitt Sensing Systems
Our measurement product competencies:
LVDTs I Inertial systems I Inclinometers I Accelerometers I IMU I
MEMS sensors I Servo-inclinometer I Conditioners
MEGGHT
smart engineering for
extreme environments
"