Toftejorg Sanitary Rotacheck0 pages
.
kyVerification of Functionality and Coverage
Toftejorg Sanitary Rotacheck
.
Application
Toftejorg Sanitary Rotacheck represents an important tool for
increasing quality assurance in tank cleaning, since it provides an
electronic means of verifying the 3D impact coverage of the Toftejorg
rotary jet head. The system is appropriate wherever rotary jet heads
are employed in cleaning tanks. The signal generated by the system
can be audible, visual or integrated into the customer’s process control
specification. Toftejorg Sanitary Rotacheck is particularly suited to
industries where improved verification standards are required, e.g.,
PAT for pharmaceutical industry, food and beverage industries.
Working principle
The Toftejorg Sanitary Rotacheck sensor is precisely installed to detect
the sweep and impact of fluid jets released as the rotary jet head
performs its cleaning cycle. From the geared operation of the cleaning
device, and by receiving the impact force from the jets, the sensor
provides verification of satisfactory operation. The Rotacheck Sensor
System is self adjusted according to the tank pressure.
Cleaning Pattern
First cycle Full pattern
The above shows the cleaning pattern achieved by a Toftejorg rotary
jet head. Toftejorg Sanitary Rotacheck enables the user to confirm that
this operation has taken place on individual tank cleaning cycles.
Standard Design
Welding adaptor for sanitary installation. 2 and 10 m (6 and 32 ft)
cable for relay connection.
Rotacheck Sensor, ATEX approved, Category 1/2 for installation in
zone 0/1 and 20/21.
Relay, ATEX approved, Category 2 for installation in zone 1/21.
Materials
Sensor and diaphragm 316L (UNS S31603).
Option: Hastelloy
Technical Data
Pressure: . . . . . . . . . . . . . . . . . . . .0.1 - 2 bar (1.5 - 29 psi)
Max. overload pressure: . . . . . . . . . .15 bar (217 psi)
Max. repetition frequency: . . . . . . . . .For sensor function 2 Hz
Duration of electrical pulse: . . . . . . . . .Min. 1.0 sec.
Mounting: . . . . . . . . . . . . . . . . . . . .By clamping into thewelding
adapter or clamped directly
on the Toftejorg SaniJet 20
Sensor cable: . . . . . . . . . . . . . . . . .2m/ 10m(6 ft / 32 ft) cable,
Ø6 mm (0.24 inch), PVC, 2
x 0.75 mm2 shielded
Operating temperature: . . . . . . . . . . .-20 to 85 °C (-4° to 185°F)
Temperature on diaphragm: . . . . . . . .Max. medium 140 °C
(284°F)
Enclosure: . . . . . . . . . . . . . . . . . . . .IP 67
Electromagnetic Noise: . . . . . . . . . . .Tested and approved
according to EU EMC
directive
Certificate
2.2 - 3.1.B - ATEX