Scientific Software Package
for M Lab Electrochemical
Workstations
SCI is an extended software package for use
with the electrochemical workstation M Lab.
SCI is able to control multiples of cells
independently even for complex tasks.
SCI offers:
- Repetitions (cycling) of any task n times
- Task lists up to 10 tasks per channel
e.g.: pre - polarisation, triangle sweep (cycled n times),
post - polarisation
Parameter
File Autosize Columns
Cell Mode | Cont Mode | Scan Mode | Range | Start | Slope | Stop | Intervall | Duration | Timestep | Record | File Name | Condition | ||
B B B | Chan 1 | F Cell On | Open Circ. | Const. | 100 nA| no Input | no Input | no Input no Input | 00:30:00| 1,0 s running O F:\TEMP\S | | |||||||
Chan 1-1 | \~ Cell On f~ Cell On | Pot.stat | Const. | Auto R. | -300 | no Input | no Input | no Input | 00:00:00 | -?- | waiting O | |||
Chan 1-2 | Pot.stat | Trian. /\ | Auto R. | -500 mV | lOmV/s | ISOOmV | 5mV | 00:07:00 | 500 [ms] | waiting # F:\TEMP\S | 5 Repeats | |||
Chan 1-3 | I- Cell On | Pot.stat | Const. | AutoR. | -500 mV | no Input | no Input | no Input | 00:20:00 | 1,0s | waiting # F:\TEMP\S | |||
Chan 1-4 | f~ Cell On | Open Circ. | Const. | 100 mA | no Input | no Input | no Input no Input | 01:00:00 | 10,0 s | waiting O F:\TEMP\S | ||||
Chan 2 | \~ Cell On | Open Circ. | Const. | -?- | no Input | no Input | no Input no Input | 00:01:00 | -?- | Stop O | ||||
Chan 2-1 | f~ Cell On I- Cell On f~ Cell On \~ Cell On | Galv.stat | Const. | 1 mA | 0,25 mA | no Input | no Input | no Input | 00:02:05 | 200 ms | waiting O | |||
Chan 2-2 | Galv.stat | Const. | 100 VA | 24,0 MA | no Input | no Input | no Input | 00:01:40 | 200 ms | waiting t | ||||
Chan 2-3 | Pot.stat | Const. | AutoR. | -?- | no Input | no Input | no Input | 00:00:00 | ■?■ | waiting O | ||||
Chan 3 | Open Circ. | Const. | -?- | no Input | no Input | no Input | no Input | 00:00:00 | -?- | Stop O |
■ Conditioned end of a task, switching over to the next, controlled by 2 conditions out of 4
end if potential >= (or <=) limit
end if current >=(or<=) limit
end if charge >=(or<=) limit
end if time >= limit value
The two conditions may be connected by either AND or OR. For each
task, separate conditions may be chosen.
Start with previous potential
If you want to start a scan from rest potential, click the check box start
condition
Halt condition
This condition shall meet absolute emerency conditions. If the condition
is met, the cell is switched off imediately.
■ Direct data export to MS Excel (.XLS) now from the data panel
- Separated data storage for chained tasks,
using automated name extensions
Condition lor Channel Chan I 2
- .-.Irt'l r.mrilKin -
I* Start w#i piev. potential
- Qrtpiimuiy tmallian, ikip ta atd pal al taajjenta
- Irgr-I rnmhrwlnn-
_ o- -."cro-daiD condiion. stir t: no-t rai ol sequenc*-
—i
- on hell condlian, slop sequence-
ruic-i
- rumbti d itpMtrit ler pill ti nauenn ■
njmbci al lapeliliam
X Cwinl
|5 Repeats,nerf step if f chaiqe'■- -123,10 rn/nsl,heltif ( currant >- SDjfJO mh)
"