Microscope Spectrometer TIDAS MSP 4000 pages
TIDAS S
MSP 400
TIDAS MSP systems from J&M offer:
- The ability to measure UV/VIS spectra of fibers in transmission mode
- All applications regarding reflectance (brightfield/darkfield), polarization or fluorescence, depending on
the chosen configuration
- Acquisition time less than one second
- Online video image and simultaneous acquisition of spectra with J&M TidasVISION software
- Flexible adjustable measurement diaphragm
- Flexible use in forensic sciences (MSP 400/800), in petrography (MSP 200) as well as in material sciences
or biology (MSP 200/400)
- Photomultiplier or CCD detection available
- Microscopes from different manufacturers can be adapted
General
MSP 400 with Zeiss microscope
The TIDAS MSP 400/800 is especially designed for the
needs of forensic scientists and can cover all applications
regarding transmission, reflectance or fluorescence, depending on the chosen configuration. Polarization as well
as UV are optional features depending on the configuration
of the microscope.
Together with police labs the system was optimized and
the software developed for an ergonomic and efficient use
in forensic laboratories.
J&M has already installed a lot of systems in Europe, USA,
South Africa and Asia.
TIDAS MSP 400
With the J&M TIDAS MSP 400 you can acquire VIS spectra from fibers in transmission as well as VIS spectra from
fibers or paints in reflection (brightfield and darkfield). The
wavelength range of the spectrometer is 360 nm to 780
nm.
For polarization experiments a polarizer with compensator
can be inserted into the optical beam. The spectral range
for polarization is limited by the polarizer to 450 nm to 700
nm. In reflectance mode the spectral range goes from 360
nm to 780 nm.
Fluorescence measurements can be done as well, several
sets of filters are available (UV, blue and green excitation is
normally standard).
Additionally, a fast scanning monochromatic light source
(260 nm to 680 nm) is also available.
A full spectrum (360 nm to 780 nm) is usually acquired in
less then one second.
Noise and acquisition speed depends on the chosen field
of interest, given by the flexible adjustable measurement
diaphragm. Minimum spot size is 2µm by 2µm using a 40x
objective.
If the microscope offers UV capabilities, the MSP 400 can
be upgraded to the MSP 800.
Sample spectra (ballpen examination)
J & M A n a l y t i k A G | W i l l y - M e s s e r s c h m i t t - S t r. 8 | D - 7 3 4 5 7 E s s i n g e n / A a l e n | Te l . : + 4 9 ( 0 ) 7 3 6 1 / 9 2 8 1 - 0 | F a x : 9 2 8 1 - 1 2 | i n f o @ j - m . d e | w w w . j - m . d e