Heating cable CI0 pages
HEATING CORD
Wrapping of heating cord is made by winding a spiral resistant wire twisted around
fibre glass support. Common resistant wires used for this purpose are made of cupronickel alloys or chroma-nickel alloys.
An heating cord allows to get both high resistance value, good flexibility and real
strength, which could not be obtained with a single resistant wire.
optional tinned copper
braid
thermoplastic rubber
insulation
resistant wire
twisted fibre
glass support
APPLICATIONS
-
making of heating cables, heating mats, heating panels and heating clothes for
freezing and air-conditioning industries and various industries,
cold room door framing cables (from 15 to 20 W/m),
cold room evaporator de-icing cables (from 30 to 35 W/m),
refrigerating cabinet de-misting (20 W/m for static cabinets – 30 W/m for
ventilated cabinets).
TECHNICAL DATA
-
resistance value : up to 30.000 Ω/m ± 10%
standard diameter : - without tinned copper braid : 2.6mm ± 0.1mm
- with tinned copper braid : 3.2mm ± 0.1mm
max. output : 35 W/m
max. voltage : 400V
max. exposure temperature (power off) : 150 °
C
optional tinned copper braid
standard insulation : thermoplastic rubber
other insulation : PVC or silicone rubber insulation on request
DOC0358B
BP 14 – P.A de la Vallée Yart – F -78640 ST-GERMAIN-DE-LA-GRANGE (France) – Tél. 33 1 34 91 04 04 –
Fax 33 1 34 89 38 18 – info@aaatelec.com
SAS au capital de 252 360 € - Siret 328 478 631 00034 – APE 297 A – N°
TVA : FR04328478631