MF Multi Fiber Test0 pages
Features Overview
Multi Fiber Test
The OP930 is based on a high resolution reflectometer
with a dynamic range from 10dB to 72dB. A reflectometer
measures the reflections of components spatially right at
the connector under test there is no mandrel wrap or
matching gel needed at the far end of the cable to be
measured.
! USB powered, plug&play data acquisition
All OptoTest instruments are equipped with the USB
1.1/2.0 compatible data port and support data rates up to
0.2 MB/s with the appropriate drivers.
OptoTest Corp. California please contact: sales@optotest.com call (805) 498 2040 or visit: www.optotest.com
MFTest
MF Test
1 3 5
2 4 6
Insertion Loss Measurement
dBm
RL
Detector
OP815
dB
Setup
Multichannel Optical Power Meter
OP710
dB
dBm
Menu
1 3 5
2 4 6
7
8 10
9
12
11
16
15
14
13
18
17
20
19
22
21
24
23
IN10
Multichannel Return Loss
OP930
7
8 10
9
12
11
16
15
14
13
18
17
20
19
22
21
24
23
dBm
RL
dB
Setup
MTP
24 Channel Return Loss & Source
Large Area Detector OPM
24 Channel Optical Power Meter
! Concurrent Dual Wavelength Measurement
The Return Loss can be measured at two wavelength
concurrently saving measurement time in the production
environment.
! CW Mode for stable Insertion Loss Measurement
The OP930 supports a CW source mode. For the Return
Loss measurement the laser sources are pulsed in the
nanosecond region. For certain measurements a
continuous modulated (CW) light signal is a required.
! Insertion Loss Measurement
The OP710 OPM is built up with individual power meters,
one per optical port. This allows for simultaneous data
acquisition over all channels which reduces the process
time The optical power meter offers a wide measurement
range from +10dbm to -80dBm with 0.001dB resolution
and tight linearity specification. Depending on the detector
it typically covers the wavelength range of 840nm to
1700nm.
! Large Area Detectors
To measure power levels on ribbon fibers terminated with
any of the MT connectors styles following large area
detector options are supported:
either a 5mm wide (for singlemode), a 10mm wide (for
The internal switch of the OP930 can be factory
configured from 2 channel to 24 channels. For a higher
channel count a single channel OP930 is connected to an
external switch of any size. All those configurations are
support by OPL-MAX and OPL-LOG.
! Mutlichannel Return Loss Measurement
! Single mode fiber 5mm Detector
Integrating Sphere
! Single mode fiber 10mm Detector
Multimode fiber Integrating Sphere
! Bare ribbon fiber, any type Integrating Sphere1
Multi Fiber Test
Applications
OPL-LOG OPL-MAX
! Serialized Cable Test
! Captures Insertion Loss and Return Loss
! Support Bidirectional Testing
! Writes directly into EXCEL files
! User configurable sequencer, connect any of 96 source
channels to any of 96 OPM channels.
! Pass/Fail criteria based on termination table.
! Timer based data acquisitions
! Captures Insertion Loss, Return Loss and Temperature
! Supports multiple instruments and optical switches
! Writes directly into EXCEL files
! User configurable sequencer, connect any of 96 source
channels to any of 96 OPM channels.