MSA 1700 pages
MSA 170
Scale model
electronic
version
MSA 170.03
Output
signals
1 Vpp
System
resolution
[µm]
Accuracy
grades
[µm/m]
Grating
pitch
[µm]
Integrated
interpolation
Max.
velocity
[m/s]
dep. on external
interpolation
±3, ±5
20
--
1.0
Max. output
frequency
[kHz]
t50
Edge separation amin
MSA 170.23
5.0
±3, ±5
20
t timest1
1.0
3.3 µs
MSA 170.63
1.0
±3, ±5
20
t timest5
1.0
500 ns
MSA 170.73
0.5
±3, ±5
20
t timest10
1.0
300 ns
MSA 170.53
0.2
±3, ±5
20
t timest25
0.64
300 ns
MSA 170.83
0.1
±3, ±5
20
t timest50
0.32
300 ns
Standard measuring lengths (ML): [mm]
50, 70, 120, 170, 220, 270, 320, 370, 420, 470, 520
Scale unit: Glass scale (α 8.5 x 10 /K)
-6
Location of reference mark (RI):
-tDistance-coded reference mark (K)
t after travelling max. 20 mm the absolute position is available
-tOne reference mark in the middle of measuring length,
t or 10 mm from either end of measuring length
t (excluding ML 50 mm)
-tOptional: one reference mark at any location, additional
t reference marks can be selected by distances of n x 25 mm
Required moving force: < 1 N
Permissible vibration: 100 m/s2 (40 to 2000 Hz)
Permissible shock: 150 m/s2 (8 ms)
Permissible temperature:
–20 °C to +70 °C (storage), 0 °C to +50 °C (operation)
Weight (approx.):
20 g + 0.17 g/mm (ML) +35 g (reading head without cable)
Power supply: +5 V ±5 %
max. 75 mA (unloaded)
1 Vpp, max. 120 mA (unloaded)
RoHS-conformity:
The Linear Encoders of the MSA 170 series comply with the
guideline of the RoHS- directive 2011/65/EU on the restriction of
the use of certain hazardous substances in electrical and electronic
equipment
Environmental sealing acc. EN 60529: IP 53
-tWith DA 400: IP 64 (see page 33)
29
"