PTC-0168 Series - AC/DC Converter Miniature, High Density, High Power Factor, 1000W, Single Output0 pages
PTC
Production & Trading Company AG FILE: PTC-0168, Page 1 of 4
Gewerbestrasse 9, P.O. Box, CH-6330 Cham, Switzerland
phone 041 740 4554, fax 041 740 4664, http://www.ptcag.ch, e-mail: ptc@bluewin.ch
PTC-0168 SERIES
AC/DC CONVERTERS
MINIATURE, HIGH DENSITY
HIGH POWER FACTOR
SINGLEUTPUT
O1000W
APPLICATIONS
Military, Ruggedized, Telecom, Industrial
SPECIAL FEATURES
.. Miniature size
.. High efficiency
.. Wide input range
.. High power factor (0.99)
.. Input / Output isolation
.. Fixed switching frequency (250KHz)
.. External synchronization capability
.. EMI/RFI filters included
.. Indefinite short circuit protection with
auto-recovery
.. Over-voltage shutdown with
auto-recovery
.. Over temperature shutdown with
auto-recovery
ENVIRONMENTAL
Meets or exceeds MIL-STD-810D
Temperature:
Operating -40°C to +85°C (baseplate)
Storage -55°C to +125°C
RELIABILITY
150'000 hours, calculated per
MIL-STD-217F at +85°C baseplate,
ground fixed.
ELECTRICAL SPECIFICATIONS
AC INPUT
AC input range: 85 to 265VAC L-N, 50/60/400Hz,
Single Phase
Efficiency: 85%, Typical
EMI/RFI:
Design to meet or exceed MIL-STD-461D
CE102, CS101, CS114, CS115,
CS116, RE101, RE102, RS101, RS103
Isolation:
1500V between Input and Output
1500V between Input and Case
DC OUTPUT (floating)
Line /load regulation:
Less than ±1% (no load to full load, -40°C to +85°C)
Ripple and noise: 100÷150mVp-p, typical (max. 1%)
Current limiting ( Hiccup):
Continuous protection for unlimited time.
Electronic over voltage protection.
Passive transzorb on outputs.
Under voltage protection (Hiccup).
Over temperature protection:
Shutdown at baseplate temperature of +105°C (±5°C)
Automatic recovery at baseplate temperature
lower than +95°C (±5°C)
Isolation:
1500V between Output and Input
200V between Output and Case